RSAH
Installation & Service Manual
Troubleshooting Flow Chart 2 – Burner Will Not Shut Down
Is
the
Red
LED (LOW
WA
TER)
On?
NO
YES
The Control
is
Sensi
ng
Low Water.
WARNING!
TURN OFF
POWER
TO BURNER
IMMEDIA
T
ELY!
CAUTIO
N – ALWAYS ALLOW A BOILER
T
O
FUL
LY COOL
BEFOR
E ADDING WA
T
ER.
�
Recheck wiring. Make sure that
burner is
wired
to
B1.
Burner
should
never fire
when red
or yellow
Is eit
h
er
Yellow LED
On?
YES
The Control h
as
Reached T
ar
g
et
or
High
Limit
T
em
p
erature.
LED is lit.
NO
Is
the
Th
ermostat
(
T-T)
Calli
ng
for Heat?
YES
The C
ontrol is
O
p
erati
ng
Normally.
NO
The burner
will continue to fire
when there
is a call
from
the thermostat
or external
z
one.
Is
the
External
Zone (ZC
-
ZR
)
Calling
for
Heat?
YES
The Control
is
O
p
erati
ng
Normally.
NO
Is
the
Low Limit Dial
NO
Set to O
FF
?
�
Check temperature displa
y.
When the
Low Limit is
set,
the HydroStat
will fire
the
burner until
the
temperature reaches the
Low Limit Setti
ng.
YES
Is t
h
ere
120 V
AC between
NO
B1 and
B
2?
Rec
h
e
ck
Wiring.
When there
is no call to fire
the
burner,
the
volta
g
e
should
be
0
volts between
B1 and
B
2.
�
Make
sure
the
burner is
wired
to B
1.
YES
Re
p
lace
Control.
If
there
is no call for
heat
(from
T-T
, ZC
-
ZR or Low
Limit), there should
be
0 V
AC between B
1-
B
2.
�
If
there
is
voltage
between
B1-B2, the
control
should
be re
p
lace
d.
Troubleshooting Flow Chart 1 - Burner Will Not Shut Down
11
Troubleshooting
(continued)