Illustrations are for representation only. Improperly located vent can damage property; 

Before cementing external vent terminations, complete all preparation 

and run start up tests per I,O&S Instructions.

Improper installation, adjustment, alteration, service or maintenance can cause severe personal injury, 
death, or substantial property damage. For assistance or additional information, consult a qualified 
installer, service agency, or the gas supplier. This boiler requires a special venting system. Read 
Installation, Operating and Service Instructions carefully before installing.

WARNING

Consult Installation Operating and Service instructions 

(I,O&S) for approximate vent de-rates

Installation Tips

Vent/Air 

Size-Inches

(mm)

Minimum 

Equivalent 

Length-Feet 

(m)

Maximum 

Equivalent 

Length-Feet 

(m)

2 (60)

2.5 (0.76)

70 (21.3)

3 (80)

2.5 (0.76)

135 (41.1)

SELECT

Horizontal 2-pipe 

low profile

Horizontal 2-pipe 

concentric

Horizontal 2-pipe

(up to 7’ separation)

Hybrid

roof and wall

vent length & diameter

UNPACK 

universal connector, lubricate heat 

exchanger gasket, install connector

SELECT

vent termination

For more vent termination options and complete 

venting information, see I,O&S Instructions.  

Do not mount components on 

either of the side access panels 

(shown removed)

Fast preventative maintenance:

Only four nuts, one gas fitting, one wire to deep heat 

exchanger access

WALL MOUNT QUICK DRILLING GUIDE:

Allow these clearances from 5/16” wall mount 

bracket holes or consult boiler I,O&S Instructions if 

tighter spacing is needed. 

26” Min.

26” Min.

26” Min.

56” Min.

LP gas conversion:

1. Turn switch 90° with 2.5mm hex wrench

2. Set fuel gas selection at boiler display

Switch

Direction

Switch

Direction

NOTE

All piping is field-supplied

111182-02

Position 1

Position 2

Model ALTA-080, ALTA-120B, ALTA-150, ALTA-180

High Efficiency Condensing Boiler

For service access:

first disconnect the spark wire at 

the heat exchanger. Gently push the 

plastic control enclosure down, then 

to the left and allow it swing down into 

the service position (as pictured).

NEAR BOILER PIPING: PRIMARY/SECONDARY KIT

Part Number: 111884-01

Boiler Return

from system

Boiler Supply

to system

Boiler Pump*

Dirt & Magentic Filter
(highly recommended)

From

System

Header Temperature Sensor
(when used)

B

A

*Supplied with boiler

A. At least eight (8) pipe diameters upstream of first tee
B. No further apart than 12" or four pipe diameters,  
     whichever is smaller.

REVISIONS

REV.

EN

DATE

DESCRIPTION

DWN

CHK

APVD

A

A

B

B

2

2

1

1

TITLE:

FIRST USE:

ITEM NUMBER:

MATERIAL:

ALTA

NEAR BOILER PIPING

HEAT ONLY

QUICK-START GUIDE

DES: EJL

CHK: 

APVD: 

SCALE: 1:10

SIZE: A

SHEET: 1 OF 1

DATE:

REVISION:

DRAWING NUMBER:

11/17/2021

TS-103-70

A

UNLESS OTHERWISE NOTED:

ALL DIMENSIONS IN INCHES.

TOLERANCES:

X.X ±.1   X.XXX ±.005

X.XX ±.03   ANGLE ±1°

PROPERTY OF

U.S. Boiler Company, Inc.

LANCASTER, PA

THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION 

AND ITS CONTENTS ARE THE SOLE PROPERTY OF U.S. BOILER 

COMPANY, INC.  ANY REPRODUCTION IN PART OR AS A 

WHOLE WITHOUT THE WRITTEN PERMISSION OF U.S. BOILER 

COMPANY, INC. IS STRICTLY PROHIBITED.

THIRD ANGLE

PROJECTION

NEAR BOILER PIPING: 

CLOSELY SPACED TEES

Install 

NO OTHER 

VALVES

 

between safety 

relief valve and boiler. 

Install in near boiler 

piping.

 18" 

Boiler Pump*

Boiler Return Connection

(1" NPT)

Boiler Supply Connection (1" NPT)

Male Safety 

Relief Valve*

(3/4" NPT)

T/P Gauge*

(1/4' NPT)

3/4" x 2" Lg. Nipple*

3/4" x 90  Elbow*

Figure 1: Primary/Secondary Manifold

*Supplied with Boiler

System Return (1 1/4" Sweat)

System Supply (1 1/4" Sweat)

Gasket

Gasket

Pump Flange Gasket*

Pump Flange Gasket*

REVISIONS

REV

EN

DATE

DESCRIPTION

DWN

CHK

APVD

A

103-215-15232

09/30/2022

INITIAL RELEASE.

CWH

SMR

CK

A

A

B

B

4

4

3

3

2

2

1

1

TITLE:

FIRST USE:

ITEM NUMBER:

MATERIAL:

ALTA

GENERAL CONFIGURATION

HEAT ONLY UNITS

DES: EJL

CHK: ---

APVD: ---

SCALE: 1:3

SIZE: B

SHEET: 1 OF 1

DATE:

REVISION:

DRAWING NUMBER:

09/03/2021

TS-103-85

UNLESS OTHERWISE NOTED:

ALL DIMENSIONS IN

MILLIMETERS.

TOLERANCES:

X ±1   X.X ±.5   ANGLE ±1°

PROPERTY OF

U.S. Boiler Company, LLC

LANCASTER, PA

THIRD ANGLE

PROJECTION

THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION 

AND ITS CONTENTS ARE THE SOLE PROPERTY OF U.S. BOILER 

COMPANY, LLC.  ANY REPRODUCTION IN PART OR AS A 

WHOLE WITHOUT THE WRITTEN PERMISSION OF U.S. BOILER 

COMPANY, LLC IS STRICTLY PROHIBITED.

A

A

B

B

4

4

3

3

2

2

1

1

Reviews: