Data transfer and control of annunciation 

The reader is provided with two-colour LED indicators and buzzer. LED and buzzer function 
according to interface type programmed and annunciation mode. 

Wiegand Interface  

Engaging  of  LED  and  buzzer  is  possible  automatically  or  by  grounding  of  corresponding 
wire according to Table 2. 

Keypad codes 

Reader  transmits  keypad  codes  in  one  of  the  programmed  modes 

–  package  or  digit-by-

digit. 
In package mode reader stores up to 10 presses of ‘0’ to ‘9’ keys and transmits package 
after the ‘#’ key press. If there are less than 10 digits pressed the leading digits filled with 
hexadecimal digit ‘F’. The ‘*’ key press clears all previous key presses. 
In  digit-by-digit  operation  mode  reader  transmits  the  key  code  immediately  after  the  key 
press with 6-bit package. The key codes are in the table below: 

Key 

Code transmitted 

key 

Code transmitted 

(hex) 

(binary) 

(hex) 

(binary) 

01 

000001 

2C 

101100 

02 

000010 

2F 

101111 

04 

000100 

31 

110001 

07 

000111 

32 

110010 

29 

101001 

34 

110100 

2A 

101010 

37 

110111 

DORADO  digit-by-digit  operation.  In  this  mode  reader  transmits  the  key  code  immediately 
after the key press with 8-bit package. The key codes are in the table below: 

Key 

Code transmitted 

Key 

Code transmitted 

(hex) 

(binary) 

(hex) 

(binary) 

F0 

11110000 

96 

10010110 

E1 

11100001 

87 

10000111 

D2 

11010010 

78 

01111000 

C3 

11000011 

69 

01101001 

B4 

10110100 

5A 

01011010 

A5 

10100101 

4B 

01001011 

Table 2. Annunciation mode:  

Data transmissions from reader comply with standard Wiegand26, Wiegand32, Wiegand34, 
Wiegand37, Wiegand40, and Wiegand42.

 

 

Buzzer 

Red LED 

Green LED 

00 

Beep on card read 

LED normally on, switch off at reading 

Blinking at reading 

01 

Control from outside 

LED normally on, switch off at reading 

Blinking at reading 

02 

Beep on card read 

Switch off 

Blinking at reading 

03 

Control from outside 

Switch off 

Blinking at reading 

04 

Beep on card read 

LED normally on, switch off at reading 

Control from host 

05 

Control from outside 

LED normally on, switch off at reading 

Control from host 

06 

Beep on card read 

Control from host 

Control from host 

07 

Control from outside 

Control from host 

Control from host 

08 

Beep  on  card  read 
Possibly  to  control 
from outside 

LED normally on, switch off at reading  
Possibly to switch off from outside

 

Blinking at reading Possibly to 
switch on from outside 

Data transfer depends on interface type. For TouchMemory interface it is identifier Type 01 
according to DS1990. 
 
Depending on length of Wiegand interface used, data transmitted for  MIFARE

® 

Classic 1K, 

may vary as shown in table below for card ID B8 26 E0 FC

The first byte in this ID is XOR 

of all bytes of ID:  

 

Direct order 

Reverse order   

Parity bits 

W26 

0-26E0FC-1 

1-FCE026-0 

W32 

B826E0FC 

FCE026B8 

Summary of Contents for Keypad MF

Page 1: ...tandard MIFARE Hi Memory MIFARE Ultralight MIFARE DESFire MIFARE CLASSIC 1k MIFARE Classic 4k MIFARE CLASSIC 7UID Features Case Material ABS plastic Color black Dimensions 119 4 х 65 4 х17 5 mm Weight 240 g Ambient Conditions Oper temp 0 C 60 C Stor temp 0 C 80 C Humidity 100 rel at 25 0 C Electrical Voltage 9 16 VDC Max current up to 75 mA Voltage ripple up to 500 mVp p Read Range Typical read ra...

Page 2: ...since it causes decreasing of reading distance Reader installation Loosen the screw at the bottom of the reader Remove the top cover remove the back plate Mount the back plate of reader on the wall using the fixtures provided see fig 1 Prepare all wires for connection and connect them to the reader in according to Table 1 and User Manual of the access control panel to be utilized Insert the reader...

Page 3: ...nsmitted hex binary hex binary 0 F0 11110000 6 96 10010110 1 E1 11100001 7 87 10000111 2 D2 11010010 8 78 01111000 3 C3 11000011 9 69 01101001 4 B4 10110100 5A 01011010 5 A5 10100101 4B 01001011 Table 2 Annunciation mode Data transmissions from reader comply with standard Wiegand26 Wiegand32 Wiegand34 Wiegand37 Wiegand40 and Wiegand42 Buzzer Red LED Green LED 00 Beep on card read LED normally on s...

Page 4: ...tributor for details Limited Warranty Integrated Technical Vision Ltd warrants that for a period of eighteen months from the date of purchase the product shall be free of defect in materials and workmanship under normal use and that in fulfillment of any breach of such warranty Integrated Technical Vision ltd shall at its option repair or replace the defective equipment upon return of the equipmen...

Reviews: