Opening door with RF ID 

To  open  the  door  user  passes  RF  ID  to  the  reader.  If  RF  ID  is  enrolled  and  the 
passage is granted, access point opens and 

panel will send “Access granted” event 

to the access control system. The reader LED becomes green. 

Exit from premises 

To exit from premises press inner door handle. Pressing the handle opens the door 
mechanically. If RTE microswitch installed panel will send 

“Request-to-exit” event to 

the access control system. 

Access denial upon entering RF ID 

Access may be denied to RF ID owner due to the following reasons (the reader LED 
is red): 

 

Cards (RF IDs) and schedules are not loaded in the panel (light off) 

 

access control panel is in unloaded state  

 

card is not enrolled in the panel  

 

card term expired  

 

RF ID passed is out of schedule  

 

RF ID passed is marked as lost or blocked  

 

the panel is in "Alarm" mode 

 

the panel is in "Blocked" mode  

 

pass count is exhausted for the temporary card (visitor). 

“Alarm” Mode 

Depending  on  the  programmed  functions  Access  point  goes  into  mode 

"Alarm"

  in 

case of unauthorized passage (Door Forced Open), opening of panel cover, entering 
RF ID recorded as lost, if AP is open too long (open time AP is exceeded), in case of 
RF ID matching attempt, opening the door with the key or the cylinder handle. 

If  Access  point 

is  in  “Alarm  mode",  passage  is 

forbidden

.  Access  point  may  be 

opened with inner door handle . 

To  exit  from  the  "Alarm"  mode  pass  the  ID  with  "Alarm  Cancel"  attribute  or  by 
command from the computer. 

"Free Pass” Mode 

There  are  circumstances  when  you  need  to  open  access  points  for  Free  pass  of 
people, such as in the case of fire, earthquake or in other emergency. For this case, 
the panel has "Free Pass" mode. 

In  "Free  Pass”  Mode  LED  of  reader  flashes  green  and  yellow  on  any  (even  not 
enrolled) ID passed. 

The  access  point  goes  into  "Free  Pass"  mode  after  the  command  of  operator  from 
the computer The access point is in "Free Pass"  mode until the command from the 
computer comes (command from the computer will not work). 

Summary of Contents for IP500

Page 1: ...1 006 Wireless access control panel U Prox IP500 Smart Handle Installation and programming manual...

Page 2: ...the panel the pins and the mode of work are described in the Description section Order of installation adjustment of external devices and panel configuration are described in Working with the device s...

Page 3: ...1 Free Pass Mode 11 Blocking mode 12 RF ID properties cards 12 The communicator 12 Wireless lock system architecture 14 Wireless lock system deployment 15 Server addresses automatic configuration for...

Page 4: ...input for door position supervision The panel can work offline or as part of the network To add it to access control network U Prox IC L control panel used U Prox IC L panel communicates with U Prox...

Page 5: ...927 5 MHz o Guaranteed range 6 20 m o U Prox HE and U Prox HW repeaters for range extension Door contact input Request to exit on inner door handle Adjusted with U Prox IP software Real time clock No...

Page 6: ...d control has two passageways and the door having single sided reader only one passageway Access point which consists of two passageways is called double sided and the point of access which consists o...

Page 7: ...ss are indicated when setting user access rights Depending on modification control panel stores up to 250 time zones 250 week schedules can be combined from these time zones Moreover control panel can...

Page 8: ...utcheon 2 RF ID reader 3 Light emitting diode 4 Card presence Detector 5 Locking Cylinder 6 Outer handle 7 Door contact optional 8 Mortise lock 9 Cover plate 10 Inner escutcheon 11 Inner handle Fig 1a...

Page 9: ...diode 4 Card presence Detector 5 Locking Cylinder 6 Outer handle 7 Door contact optional 8 Mortise lock 9 Cover plate 10 Inner escutcheon 11 Inner handle Fig 1 U Prox IP500 panel installed on the door...

Page 10: ...sounds within range of the infrared sensor obstacle is more than a minute Control panel also sent event Reader sensor trouble Panel operation The panels supplied unloaded with factory settings below...

Page 11: ...count is exhausted for the temporary card visitor Alarm Mode Depending on the programmed functions Access point goes into mode Alarm in case of unauthorized passage Door Forced Open opening of panel...

Page 12: ...ters event Alarm cancelled and puts the door to Normal mode If the card that has no right to cancel the Alarm is passed the door will remain in the same state Access denied Alarm Status event recorded...

Page 13: ...est signals repeated every 2 minutes Attention The delay of delivery of the operator command to U Prox IP500 Smart Handle may last up to 2 minutes i e the period of the test signal Panel provides encr...

Page 14: ...i e make decision about the access using data uploaded beforehand U Prox IC L control panel routes data from the allowed U Prox IP500 Smart Handle wireless panels via U Prox HE and U Prox HW repeaters...

Page 15: ...cols DHCP for instance allowed to provide the plug and play principle The mode of the automatic server address configuration in the panels eases the wireless lock system deployment significantly The d...

Page 16: ...access control system server about itself as a new device in the local network Despite it is broadcast announcement it is limited with one range local network and active network equipment That s why t...

Page 17: ...the local network Despite it is broadcast announcement it is limited with one range local network and active network equipment That s why the IP addresses of the U Prox IC L panel are to be set manual...

Page 18: ...tem database e Operator must upload U Prox IC L control panel after the U Prox IP500 Smart Handle panel added to the DB f Operator must upload U Prox IP500 Smart Handle panel after the adjustment it i...

Page 19: ...tcheon 2 Reader 3 Connection cable 4 Panel board 5 Door contact magnetic optional 6 Mortise lock and cover plate screws 7 Mortise lock 8 Cover plate 9 Cylinder retainer pin 10 Rectangle 11 Inner escut...

Page 20: ...n 2 Reader 3 Connection cable 4 Panel board 5 Door contact magnetic optional 6 Mortise lock and cover plate screws 7 Mortise lock 8 Cover plate 9 Cylinder retainer pin 10 Rectangle spindle 11 Inner es...

Page 21: ...ange handles position for installation on desired door side proceed A Outer escutcheon See Fig 9 1 Release stopper rotating it on 900 2 Alter handle position 3 Return stopper to initial position B Inn...

Page 22: ...10 fell into corresponding holes in the mortise lock and outer escutcheon precisely 10 Fix inner 11 and outer 1 escutcheons with screws 13 11 Insert the cylinder 16 if used and secure it with cylinde...

Page 23: ...prox com 23 Fig 10a Cable running model for Lockwood 3582 Mortise Lock 89 9 mm Fig 10b Cable running model for Lockwood 3572 Mortise Lock 64 mm Opening for cables and DC wire Opening for cables and D...

Page 24: ...ss point states without the door contact proper operation Panel generates the Entry occurred message on inner handle press when the door contact is absent To enable door contact set the Z1 zone as A d...

Page 25: ...Fig 13 Battery replacement Return to factory settings To Return to factory settings 1 De power control panel remove at least one battery 2 Press and hold FactSet button 3 Supply power to control panel...

Reviews: