background image

http://u-prox.com

 

 

13

 

2. 

If DHCP mode is ON, the dynamic IP address obtain routine will start 

3. 

The panel automatic configuration mode starts if the access control system 
IP address (IP or DNS name) is not set: 

a. 

Panel  sends  data  packages  announcing  access  control  system 
server about itself as a new device in the local network 

Despite  it  is  broadcast  announcement,  it  is  limited  with  single 
range  local  network  and  active  network  equipment.  That’s  why 
the  IP  addresses  of  the  access  control  system  server  are  to  be 
set manually for networks with sophisticated topology. 

b. 

The  system  will  warn  operator  after  the  receiving  of  the  data 
package  from  the  new  panel.  Operator  must  add  panel  to  the 
system database (DB). 

c. 

After  the  panel  added  to  the  DB  it  receives  the  answer  from the 
access control system server. The address of the access control 
system  server  recorded  into  the  control  panel  and  it  stops  to 
broadcast. 

d. 

Operator  has  to  upload  panel  after  its  adjustment  recorded  into 
the DB. Panel becomes associated to the certain access control 
system  server,  eliminating  panel  control  capture  with  another 
system.  

Return  panel  to  the  factory  settings  to  eliminate  the  panel 
association to the system 

e. 

In  the  case  of  access  control  system  server  IP  address  change 
panel will initiate the automatic configuration routine, but the data 
exchange will be possible with previously connected system only.  

Interaction with elevator equipment 

U-Prox WRS485  interface  convertor  connected  to  the  U-Prox  IC  E  control  panel  to 
provide the noise-resistant and long-range RS-485 interface to the reader, placed in 
elevator cabin. 

To  control  the  loops  of  the  floor  selection  buttons  up  to  four  U-Prox  RM  relay 
modules connected to the U-Prox IC E control panel. The U-Prox RM relay terminals 
connected  in  series  with  buttons’  terminals.  Connect  relay  terminals  in  way  that 
provides  the  floor  selection  buttons  operation  in  case  of  U-Prox  RM  power  failure. 
Z1…Z8 zone loops used for floor selection buttons state supervision and for buttons 
remote  connection  control.  On  pressing  floor  selection  button  U-Prox  IC  E  
generates message "Access granted to the floor." 

Summary of Contents for IC E

Page 1: ...1 003 Access control panel U Prox IC E Elevator control Installation and programming manual ...

Page 2: ...ustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers situated on the territory of countries enlisted in the warranty card Warranty and technical support performed on the territory of the country where the customer applied for warranty or free service T...

Page 3: ...larm Mode 9 Free Pass Mode 10 Blocking mode 10 RF ID properties cards 10 Communicator operation 11 System deployment 12 Interaction with elevator equipment 13 How to work with the device 15 Connection 15 Mount recommendations 16 Modules and interface convertors connection 16 RS 485 connection recommendations 18 Communication 18 Wired computer network 18 Panel program order 20 Service maintenance 2...

Page 4: ...y elaborated technical and design solutions easy installation communication over a computer Ethernet network non volatile memory and the clock PoE power up ability protecting the communication ports from short circuit over voltage and reverse polarity all allows to use the panel to build a variety of Access Control Systems ACS from the system for a small office to the clock house of a large enterp...

Page 5: ...oor supervision devices like door contact RTE button etc and door locking device In case of elevator control panel access point is the floor selection button or the set of buttons enabling person s access to the desired floors according to his access rights For instance the turnstile with two way passes has two Access points one for entrance and the other one for exit door of this type is called d...

Page 6: ...a U Prox IC E modification 1 Figure 2b U Prox IC E modification 2 Location of jumpers and connectors on control panel board and their function is shown in Fig 2 a and b 1 The Enclosure 2 Ethernet port 3 Micro USB B port 4 Reset button 5 Connectors 4 5 2 3 5 6 1 5 1 2 3 4 1 The Enclosure 2 Reset button 3 Panel board 4 Micro USB B port 5 Ethernet port 6 Connectors ...

Page 7: ...12V 12V External 12V power supply connection GND GND A A RS 485 bus for reader convertors and U Prox RM relay modules connection B B USB Connector USB micro B USB Connector For network settings configuration and firmware upgrade Jumper BAT BAT For memory and Real Time Clock backup battery switch TERM TERM RS 485 terminal resistor commutation Button FUNK FUNK Service button ...

Page 8: ...een and yellow alters no sound Blocking mode Red and yellow alters no sound Alarm Red lights continuously no sound Card enrollment Green blinks once per second no sound Initiation No lights no sound Download Red lights continuously no sound PIN code wait Yellow blinks once per second no sound Access granted Green lights continuously no sound Access denied Red lights continuously sounds continuousl...

Page 9: ...ader LED becomes green User may select floor with button during adjusted time Access denial upon entering RF ID Access may be denied to RF ID owner due to the following reasons the reader LED is red Cards RF IDs and schedules are not loaded in the panel access control panel is in unloaded state card is not enrolled in the panel card term expired RF ID passed out of schedule entered RF ID is marked...

Page 10: ...locking mode until the command from the computer RF ID properties cards Code RF ID card code Each card has a unique code which is set at the time of its manufacture It consists of 10 hexadecimal digits PIN code Additional code is assigned to the card It consists of no more than six decimal digits It can be used together with readers that have a built in keyboard Enter PIN code with the reader s ke...

Page 11: ...ta from the readers U Prox RM modules and U Prox WRS485 convertors processed and access event messages are sent to the access control system server Panel Communicator operates in notification mode that means that data transmission to the access control system server is initiated on the access event U Prox IC E panel connected to the computer network with wired Ethernet Both local enterprise comput...

Page 12: ... of given IP address of router 4 Determine accessibility of ACS server IP or DNS name 5 Periodic sending of test signals 6 If there is send the events Waiting for server commands 7 Failure transition to the second specified IP address of router System deployment The use of the existing computer network infrastructure standard network protocols DHCP for instance allowed to provide the plug and play...

Page 13: ...rded into the DB Panel becomes associated to the certain access control system server eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel association to the system e In the case of access control system server IP address change panel will initiate the automatic configuration routine but the data exchange will be possible with previously...

Page 14: ...ve EMRG inputs In normal state short the loop connected to this input terminals to the ground GND terminal On input loop break module depowers all relays and all floor selection buttons become available Figure 5 Connection schema Zone loops supervised with 2 2 kOhm end of line resistors and have three states Normal Opened and Shorted When all zone loops are in Normal state module waits for relay a...

Page 15: ...e 6 Loop s connection examples How to work with the device U Prox IC L control panel shipped in the plastic enclosure without the power supply Dimensions marked on the Fig 7 Connection 1 Perform initial network setup of control panel that specifies settings of network parameters with utility Configurator via USB port before installation if it is impossible to adjust them automatically 2 Prepare th...

Page 16: ...e wall perform actions Modifaction 1 see Fig 8a Open the enclosure cover remove the board and mark fixing holes using the enclosure bottom as template Pull the power wiring through the opening in the enclosure Fix the enclosure bottom Connect the power wiring Modifaction 2 see Fig 8b Perform the marking of holes using the accompanying drawing Fix the enclosure Connect the wires Modules and interfa...

Page 17: ...http u prox com 17 Figure 9 Control panel relay modules intrface convertors and reader connection on RS 485 bus ...

Page 18: ...cation mode that means that data transmission to the access control system server is initiated on the access event Operating in the computer network U Prox IC E control panel provides encryption protection of the data and commands with 256 bit key unique serial number supervision and communication channel supervision with periodical test messages Wired computer network The Ethernet interface is us...

Page 19: ...orm Adjust panel network settings don t adjust when use DHCP o IP address o Subnet mask o Gateway router Internet 1 IP address no need in local network o Gateway router Internet 2 IP address miscellaneous o DNS server 1 IP address if data send to the domain name o DNS server 2 IP address miscellaneous if data send to the domain name Adjust communication to the server no need in automatic configura...

Page 20: ... maintenance Return to factory settings To return to factory settings 1 De power control panel 2 Press and hold FUNC button 3 Supply power to control panel 4 Wait for 10 seconds until LED diode lights and release FUNC button 5 LED diode will flash 6 times that means factory settings restored Switching to programming mode To put access control panel in programming mode do the following 1 Connect ca...

Page 21: ...http u prox com 21 Reference for device installation modification 2 ...

Reviews: