U-Line Wine Captain U-2224ZWCINT-00B User Manual & Service Manual Download Page 10

USER GUIDE

Side-by-Side Installation 1

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Side-by-Side Installation

OTHER SITE REQUIREMENTS

Side-by-Side Installation

Units must operate from separate, properly grounded 
electrical receptacles placed according to each unit’s 
electrical specifications requirements.

Cutout width for a side-by-side installation is the total of 
the widths listed under Cutout Dimensions in each unit’s 
Installation Guide. Each door can be opened individually 
(one at a time) without interference.

However, to ensure unobstructed door swing (opening 
both doors at the same time), 1/4" (6.4 mm) of space 
needs to be maintained between the units.

Hinge-by-Hinge Installation (Mullion)

When installing two units hinge-by-hinge, 13/16" (22 mm) 
is required for integrated models. Additional space may be 
needed for any knobs, pulls or handles installed. 

Stainless steel models which include the standard stainless 
handle will require 4-9/16" (116 mm) to allow both doors 
to open to 90° at the same time.

1/4" (6 mm)

13/16" (22 mm)

4-9/16" (116 mm)

10

Summary of Contents for Wine Captain U-2224ZWCINT-00B

Page 1: ...SER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 2000 Series 2224ZWC 24 Dual Zone Wine Captain RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...allation Door Swing Door Stop Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Sabbath Mode Airflow and Product Loading U Line Wi...

Page 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Page 4: ...ury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...

Page 5: ...reezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulatio...

Page 6: ...10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of dir...

Page 7: ...to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that ha...

Page 8: ...he front grille plinth strip base fascia must NOT be obstructed CAUTION Unit can NOT be installed behind a closed cabinet door U Line products are designed and manufactured to be installed in the spec...

Page 9: ...Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 3 5 16 84 mm 33 11 16 to 34 11 16 856 to 881 mm 23 5 8 600 mm Not Including Handl...

Page 10: ...t Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4...

Page 11: ...drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 4 Install 3 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT Si...

Page 12: ...total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust...

Page 13: ...panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish application and cure times 3 Apply double sided...

Page 14: ...fascia When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille pli...

Page 15: ...llow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door...

Page 16: ...pproximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should s...

Page 17: ...that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This would...

Page 18: ...ve caps from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 in...

Page 19: ...the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the fac...

Page 20: ...ghts Press and release Leave interior light on for 3 hours Adjust temperature Press and release The zone you are setting will have its light turned on top zone first Press to adjust set point temperat...

Page 21: ...ain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will f...

Page 22: ...airflow to perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between th...

Page 23: ...subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and Wi...

Page 24: ...e presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurateu...

Page 25: ...at sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine b...

Page 26: ...Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable s...

Page 27: ...les so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustrations below Racks 1 through 5 Rack 6 Larger...

Page 28: ...tchBrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be poss...

Page 29: ...drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in a...

Page 30: ...n necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any ty...

Page 31: ...cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engageme...

Page 32: ...t is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...

Page 33: ...listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air mo...

Page 34: ...openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be enabl...

Page 35: ...LLOW EVAP VALVE EVAP VALVE 1 10 CONTROL BOARD L T ZONE TEMP 9 1 L T EVAP L T DOOR SWITCH AMBIENT R B DOOR SWITCH FUSE 6 1 10 5 R B LIGHT L T LIGHT COND FAN L T EVAP FAN R B EVAP FAN R B ZONE TEMP R B...

Page 36: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Page 37: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Page 38: ...54040 00 15 Hinge covers 2 pcs 80 54001 00 16 Hinge mounting hole covers 80 54024 00 17 Hinges 2 w screws and covers 80 54013 00 18 By pass valve 80 54180 00 19 LED light strip and cover assy 80 5400...

Page 39: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Page 40: ...federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fire extinguisher...

Page 41: ...equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing a...

Page 42: ...he system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the system must be pur...

Page 43: ...e access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the...

Page 44: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Page 45: ...st strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and...

Page 46: ...utputs located on the relay power board Included in this section are some diagnostic tips and of course if additional help is required please contact the U Line Corp Customer Care Facility at 1 800 77...

Page 47: ...des Refer to 14 Error Log in Service Mode Thermistor failure Check Error Log in Service Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoi...

Page 48: ...rload and will remain deactivated until the overload switch cools This could take some time It is important to allow the compressor at least 5 minutes off time between relay cycles 2 Toggle the relay...

Page 49: ...s REED SWITCH A reed switch is used to monitor door state When the door is closed magnetic force pulls the reed to its contact and closes the circuit which turns the light and display off When the doo...

Page 50: ...tes through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates light for...

Page 51: ...the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the control for demonstrations The unit can be left in this mode indefinitely SERVICE MODE This...

Page 52: ...TACTING TECH LINE 800 779 2955 9 THERMISTOR 2 SET POINT MINUS OFFSET This shows the thermistor reading with offsets taken into account 10 Does not apply to this model 11 THERMISTOR 4 SET POINT MINUS O...

Page 53: ...apply to this model 18 Does not apply to this model 19 INDIVIDUAL COMPONENT TOGGLE 20 MODEL NUMBER INDICATOR Displays the two digit model number of the specific unit See model list table 21 LIGHT ALL...

Page 54: ...conds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed d...

Page 55: ...ator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Page 56: ...section This unit has five thermistors Thermistor one Zone Located along the right hand side wall in the top left compartment It is used to maintain the operating temperature within that zone Thermis...

Page 57: ...normally Refer to defrost section Ambient Thermistor If the thermistor fails the unit will operate normally Thermistor Resistance Data Temp F Temp C Nominal Resistance OHMS 40 40 169157 31 35 121795 2...

Page 58: ...C 1224 RF 12 45 15 9 1215 1224 2218 2245 2224 2260 WC ZWC 12 45 45 7 1215 1224 2218 2245 2224 2260 R RSOD RDC BEV DC DWR RGL 12 45 42 6 CO29 F 12 18 n a CO1224 F 12 18 45 7 1224FZR Freezer Mode 6 45...

Page 59: ...nty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied or...

Reviews: