www.U-LineService.com
4
09/2008
1075WC
PRODUCT DIMENSIONS
Please note that the unit has adjustable feet that can add
one additional inch to height during leveling or to match
adjacent cabinets (see
Figure 9
).
DOOR SWING/CLEARANCES INFORMATION
All 1075 units have a zero clearance for the door to open
90° (see
Figure 3
). Stainless units require a minimum of
2" door clearance to accommodate the handle if the unit
is installed next to a wall or similar type of structure
.
OTHER SITE REQUIREMENTS
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on
Page
7
.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:
• The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures.
• For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
• In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
• U-Line does not recommend installation of glass front
models (Wine Captain
®
wine storage models and
Beverage Centers) as well as the Combo Drawer model
(Refrigerator/Freezer/Ice Maker) outdoors, or in
tropical climates where high humidity and dew point
are present on a regular basis, unless air-conditioning
(typical 72°F, 75%RH) will be used.
SIDE-BY-SIDE INSTALLATION INSTRUCTIONS
For a complete refreshment center, install two of the
following 1175/1075 series units side by side: 1175R,
1175WC or a 1075 BEV Center. Note that each Side-By-
Side Installation will be different.
• Cut-out width for a side-by-side installation is the total
of the widths listed under
Cut-Out Dimensions
in each
unit’s Installation Guide.
For example:
Placing a 1175R next to an 1075 series unit would
require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"
• No trim kit is required. However, 1/4-inch space needs to
be maintained between the units to ensure
unobstructed door swing.
• Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
Electrical Specifications
.
34-1/8"
23-15/16"
25-7/16"
Including
Handle
ULIN_1060_A
Figure 2
Wall
2" Min.
90°
Door Swing
20-7/8"
25-1/4"
Wine Captain 1075WC
Figure 3