SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Control Operation - Service 4
USER GUIDE
u-line.com
E1:
Thermistor 1 open.
E2:
Thermistor 2 open.
E3:
Thermistor 3 open.
E4:
Thermistor 4 open (Does not apply to this
model).
E5:
Thermistor 1 shorted.
E6:
Thermistor 2 shorted.
E7:
Thermistor 3 shorted.
E8:
Thermistor 4 shorted (Does not apply to
this model).
E9:
Door 2 (lower) open.
P1:
Pump Circuit open (Does not apply to this
model).
15.
CLEAR ERROR LOG
To clear errors, press and hold
(5 seconds)
when CLR is flashing.
16.
THERMISTOR
—
1 DIFFERENTIAL
This number should not be adjusted.
17.
Does not apply to this model.
18.
Does not apply to this model.
19.
INDIVIDUAL COMPONENT TOGGLE
Display #
Relay/Output
0
Exit
2
Relay 2
3
Relay 3
4
Relay 4
5
Relay 5
6
Relay 6
7
Relay 7
8
DC Output 1
9
DC Output 2
10
DC Output 3
11
DC Output 4
12
DC Output 5
SEE RELAY/OUTPUT CHART
20.
MODEL NUMBER INDICATOR
Displays the two-digit model number of the
specific unit. See model list table.
21.
LIGHT ALL LED SEGMENTS
This will illuminate all the LEDs on the display
to ensure they work properly.
22.
VIEW DEFROST CYCLES
Displays the number of defrosts that have
occurred in the past 24 hours.
23.
VIEW COMPRESSOR RUNTIME
This will show the number of minutes the
compressor has run in the prior cycle (or
current cycle if the compressor was running
when service mode was entered).
24.
ACTIVATE DEFROST/HARVEST
Turns on the hot gas bypass valve allowing
hot gas to circulate through the evaporator
causing frost to melt.
25.
RESTORE FACTORY DEFAULTS
Will restore all adjustable functions to their
factory settings.
26.
SOFTWARE VERSION
—
MAIN BOARD
Displays software version of the main control
board.
27.
SOFTWARE VERSION
—
USER INTERFACE
Displays software version of the user
interface.
28.
LOG IN PERIOD
Factory use only - do not adjust.
29.
FACTORY TEST MODE
Should be 0.
0.
EXIT SERVICE MODE
MODEL LIST
1000
MODEL
INDICATOR
2000 (120V)
MODEL
INDICATOR
2000 (230V)
MODEL
INDICATOR
1215R
07
2218R
05
2245R
55
1215WC
12
2218RGL
04
2245DC
54
1224BEV
13
2218WC
06
2245WC
56
1224DWR
08
2224BEV
00
2260DC
50
1224R
14
2224FZR
11
2260FZR
57
1224RF
09
2224R
02
2260R
52
1224RSOD
10
2224RGL
01
2260RDC
51
1224WC
15
2224WC
03
2260WC
53
CLR1215
18
2224ZWC
59
2260ZWC
58
CO1224F
19
ADA24R
17
Summary of Contents for Wine Captain 1000 Series