MAINTENANCE

CLEANING

After use, clean residue from top and bottom of heater blade 

with Scotch-Brite™ Pad (S-11724). Brush until metal is bright.

•  Remove heater cover. To remove blade, pull back on 

spring-loaded arm. (See Figure 10) Lift blade assembly 

up and forward to release. DO NOT LOOSEN SET SCREWS. 

Reverse to reassemble.

Use Air Gun or ULINE Air In A Can (S-6771) to clean parts of 

plastic residue. (See Figure 11)

LUBRICATION

Weekly (more often with high usage) – Apply a few drops of 

10-20W machine oil to oiling points. (See Figure 11) Make sure 

to clean dirt and debris from parts before applying oil.

ADJUSTMENTS

STRAP WIDTH

Make adjustments at the Strap Outlet and the Strap Inlet.

1.  Machine comes preset for 1/2" strapping.

2.  Strap Inlet: Loosen two black screws with Allen wrench. Set 

the Strap Inlet guide about 1/16" wider than the strapping 

you are using and align with the Strap Outlet. Retighten 

socket screws. (See Figure 7)

3.  Strap Outlet: Loosen two Phillips head screws. (See shaded 

areas in Figure 6) Adjust the width to accept width of strap 

you are using. Set the strap outlet guide at 1/2" for 1/4" and 

3/8" strapping and 5/8" for 1/2" strapping. Retighten screws.  

(See Figure 8)

TENSION ADJUSTMENT

1.  The strap tension adjustment handle is located at the 

back of the machine. (See Figure 9)

2.  Machine comes preset at 0 tension. Recommend starting 

at middle point of tension gauge bar.

3.  Turn the handle clockwise to increase tension; 

counterclockwise to decrease tension.

9  12

15

9

6

12

15

TIGHT              LOOSE

 

π

  CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

1-800-295-5510

uline.com

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11

Strap Inlet

Strap Outlet

Tension 

Adjuster

Blade 

Assembly

Set 

Screws

Clean 

Blade

Spring Loaded Arm

Air and 

Oiling Points

Reviews: