background image

USER GUIDE

Ice

Ice

ICE MAKER OPERATION

When the ice bucket is full, the ice making mechanism will 
shut off. However, the refrigeration system will continue 
to cool and maintain the ice supply.

NOTICE

Do not place cans or bottles in the ice 
compartment because they will freeze.

To turn off ice production:

 Raise the bin arm into 

an upright and locked position. The unit will preserve 
temperature for ice storage. 

NOTICE

If not intending to use the ice maker, turn the 
water supply valve off. It is also important to 
raise the bin arm of the ice maker (see above). 
Failure to raise the bin arm may result in damage 
to the water valve.

Certain sounds are normal during the unit’s operation. You 
may hear the compressor or fan motor, the water valve, 
or ice dropping into the ice bucket.

CAUTION

!

NEVER use an ice pick, knife or other sharp 
instrument to separate cubes. Shake the ice 
bucket instead.

During periods of limited use or high ambient 
temperatures, it is common for cubes to fuse together. 
Gently shake the bucket to break apart cubes. If not using 
the ice maker regularly, empty the ice bucket periodically 
to ensure fresh cubes.

It is normal for cubes to appear cloudy. The cause is air 
trapped in the water because of fast freezing. It is not 
caused by the health, taste or chemical make up of the 
water. It is the same air that is in every glass of water you 
drink.

Remove the ice bucket for emptying and cleaning. To 
remove the ice bucket, raise the bin arm and remove the 
bucket from the ice compartment. Use the ice bucket for 
ice storage only.

OFF

ON

21

Summary of Contents for UHRI124BS01A

Page 1: ...USER GUIDE SERVICE MANUAL Model UHRI124 BS01A...

Page 2: ...et General Installation Grille Installation Door Swing Door Adjust Interior Adjustments Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Cont...

Page 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Page 4: ...oderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do n...

Page 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Page 6: ...ures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating e...

Page 7: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Page 8: ...NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE ICE MAKER AND BIN 22 1 8 562 mm 13 1 8 333 mm 18 3 8 467 mm 10 267 mm 26 679 mm 22 572 mm 24 3 8...

Page 9: ...cording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown bel...

Page 10: ...ater line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation WARNING Connect to...

Page 11: ...r feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on water supply and check for leaks 8 Reinsta...

Page 12: ...oles and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if...

Page 13: ...ing s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is corre...

Page 14: ...HARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille 2 from unit Installing the grille 1 Align cabinet and grille holes and secur...

Page 15: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Page 16: ...not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 Tigh...

Page 17: ...nge 1 Remove bottom hinge from cabinet using a 1 4 socket 2 Remove corresponding screws on opposite side of cabinet On some models there may be a nut behind one or both screws on either side Install b...

Page 18: ...abinet Available at u line com To install the kit 1 Remove grille see GRILLE INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligning holes of shell accessory with the...

Page 19: ...rned off during installation simply press and the unit will immediately switch on To turn the unit off press If the temperature displayed is different than selected the unit is progressing towards the...

Page 20: ...ble Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so until user resets mode unit continue...

Page 21: ...ration You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp instrument to separate cubes Shake the ice bucket...

Page 22: ...an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage 3 Turn the adjusting screw toward the minus sign clockwise for smaller cubes or toward the plus s...

Page 23: ...es Not all bottles and cans will fit on every shelf and wine rack Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capaciti...

Page 24: ...e shelf from unit by pulling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where y...

Page 25: ...eel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels us...

Page 26: ...tive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow t...

Page 27: ...g on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The co...

Page 28: ...allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 Clean the system See CLEANING 6 The door must remain open to prevent formation of...

Page 29: ...h a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may be heard when...

Page 30: ...TO COMPRESSOR PURPLE WHITE PAN HEATER 115 VOLT PLUG ORANGE RED PURPLE BLACK YELLOW LIGHT BLUE BLACK WHITE If Applicable CONTROL BOARD FUSE WATER VALVE HOT GAS VALVE ICEMAKER ASSEMBLY SW C GREEN W YELL...

Page 31: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Page 32: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Page 33: ...ASKET DOOR 80 54213 00 16 GLASS SHELF ASSEMBLY 80 55660 01 17 GRILLE ASSEMBLY 24 BLACK 80 55597 01 18 HINGE ASSEMBLY BLACK 80 55595 02 19 ICE BUCKET 80 54370 00 20 ICE MAKER ASSEMBLY R600 80 54589 01...

Page 34: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Page 35: ...ust observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fi...

Page 36: ...pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system p...

Page 37: ...is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the sy...

Page 38: ...ll a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minu...

Page 39: ...cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room te...

Page 40: ...h are not hot or frozen Compressor Specifications EM2C46CLC 115V REFRIGERANT R600a VOLTAGE 115V 127V FREQUENCY 50Hz START WINDING 5 20 8 Q at 25 C 77 F RUN WINDING 7 19 8 Q at 25 C 77 F LRA 8 0A FLA 2...

Page 41: ...ricate bin arm pivot points or loosen bin arm lever screw Water will not stop filling Water switch inoperable closed Replace water switch Solenoid valve inoperable Replace solenoid valve Stalled ice m...

Page 42: ...sition drain line in drain pan Crack in water line Replace water line Water leak inside unit Ice maker assembly fill cup obstructed Remove obstruction Fill ice cup and fill tube out of alignment Align...

Page 43: ...y cold near inlet outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal in vacuum Warm near room temperature Very hot Top passes warm lower passes cool near ro...

Page 44: ...Water Adjustment Bin Switch Failure NO NO EVERYWHERE INTERMITTENT AT 3 00 YES NO AT 12 00 DOES THE UNIT HARVEST ICE IF THE EJECTOR BLADES ARE MOVED BY HAND OR WITH A WRENCH WHERE DO THE EJECTOR BLADE...

Page 45: ...rigeration Defrost Mode Bypass solenoid valve open Refrigerant flows through bypass system Vapor flows from condenser to evaporator without a phase change Figure 1 Frost Free Refrigeration System SOLE...

Page 46: ...Figure 2 Freeze Cycle SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL C NC MOTOR FAN LOAD OVER black RELAY START COMP SWITCH OFF ON black black blue black CONTROL T...

Page 47: ...up the ice maker will not harvest Figure 3 Harvest 1 Cycle Hold Switch in Normal Position SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL C NC MOTOR FAN LOAD OVER...

Page 48: ...r pulsates until mold heater warms and ice releases Figure 4 Harvest 2 Cycle Hold Switch in Switched Position SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL C NC M...

Page 49: ...Temperature control terminals 2 and 3 have closed during harvest cycle Next freeze cycle begins with power to the compressor and condenser fan SWITCH LIMIT orange black black black MOTOR MAKER ICE MO...

Page 50: ...maker thermostat located behind grille open Freezer control closed and refrigeration system is operating Harvest Cycle 1 Ice maker thermostat closed Refrigeration system operating If bin arm is up the...

Page 51: ...switch is to open in the event of an overheating condition This bi metal thermostat is normally closed and does not initiate the ice harvest cycle The ice harvest cycle is initiated by a double throw...

Page 52: ...lock position by turning the 5 16 hex head on the small brass gear counterclockwise 4 7 Remove three screws from wall of freezer housing 5 8 Remove ice maker assembly 9 Place new ice maker assembly in...

Page 53: ...side of new ice maker 12 Replace parts in reverse order of removal 13 Reconnect all wires 14 Insert capillary tube into ice maker sensing tube 15 Insert water inlet tube 16 Apply permagum to all exit...

Page 54: ...and reset VIEWING ACTUAL TEMPERATURE In viewing temperature in these modes any offsets are taken into account This means that if you place a therm istor in a known temperature let s say ice water it...

Page 55: ...display will flash and then toggle from set point to temperature in unit seconds The display will change units or ACCESS SERVICE MODE To access the service menu for this model remove the two screws t...

Page 56: ...T DURATION 0 TO 99 MINUTES The length of the defrost can be adjusted 0 to 99 minutes long The other defrost parameters still apply Lengthening a defrost may cause higher than normal temperatures in th...

Page 57: ...s will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot ga...

Page 58: ...ing digits appear 3 5 seconds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will ap...

Page 59: ...2 Evap Fan Cond Fan 22 RE336 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 23 RE515 1A Compressor Light 1 Light 2 Evap Fan Cond Fan 25 RE524 1A Compressor...

Page 60: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Reviews: