background image

Copyrigh

U-Line Corporation. All Rights Reserved. |  Publication Number 30379 |  

1

1

/20

2

2

 Rev. 

P

 

U-Line Corporation (U-Line) Limited Warranty

One Year Limited Warranty 

For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours.  

Two Year Limited Warranty (5 Class Product) 

For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours. 

Available Second & Third Year Limited Warranty 

In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date 
of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date 
of purchase at u-line.com and provide proof of purchase.

 Nugget Ice Machine proof of purchase must include the purchase of an in-line 

water filter and filter head to qualify for this additional limited warranty.

 

Five Year Sealed System Limited Warranty 

For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be 
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line 
under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service 
provided during normal business hours. 

Terms 

These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten 
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, 
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and 
maintained in accordance with your product’s User Guide. 

The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any 
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of 
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal 
rights, and you may also have other rights which vary from state to state.   

Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of 

merchantability 

or any 

warranty 

fit for a particular purpose

 is limited to the duration of these warranties, and only extends to five years in duration for the parts 

described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitations may not apply to you. 

The warranties only apply to the original purchaser and are non-transferable.

The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.

The warranties apply to units operated outside only if designed for outdoor use by model and serial number.

U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties.

Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.

The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.

In-home instruction on how to use your product is not covered by these warranties.

Food, beverage, and medicine loss are not covered by these warranties.

If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.

Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects.

Signal issues related to Wi-Fi connectivity are not covered by these warranties.

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 

8900 N. 55

th

 

Street, Milwaukee, WI 53223 • u

-

line.com • onlineservice@u

-

line.com • +1.

414

.

354

.

0300

 

44

Summary of Contents for UHFZ124-SS01A

Page 1: ...USER GUIDE SERVICE MANUAL Model UHFZ124 SS01A...

Page 2: ...tallation Grille Installation Door Swing Door Adjust Interior Adjustments Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation...

Page 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Page 4: ...oderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do n...

Page 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Page 6: ...ures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating e...

Page 7: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Page 8: ...n the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 4 102 mm 7 178 mm 24 610 mm 24 1 4 616 mm 34 1 8 867 mm to 35 1 8 892...

Page 9: ...cording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown bel...

Page 10: ...oles and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if...

Page 11: ...ing s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is corre...

Page 12: ...HARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille 2 from unit Installing the grille 1 Align cabinet and grille holes and secur...

Page 13: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Page 14: ...of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the...

Page 15: ...models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Install hinge w...

Page 16: ...abinet Available at u line com To install the kit 1 Remove grille see GRILLE INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligning holes of shell accessory with the...

Page 17: ...cts actual temperature inside unit If the temperature displayed is different than selected the unit is progressing towards the selected temperature Time to reach set point varies based upon ambient te...

Page 18: ...ay will show the default set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display...

Page 19: ...w and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille internal fans or vents at any time or the unit will not perform as expe...

Page 20: ...ils from the cabinet To reinstall 1 Align the left and right basket channels with the tracks in the cabinet Ensure an even track engagement on both sides by gently pushing the basket into the cabinet...

Page 21: ...eel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels us...

Page 22: ...tive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow t...

Page 23: ...n necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type...

Page 24: ...evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open...

Page 25: ...akes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before d...

Page 26: ...ing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of th...

Page 27: ...t White light L T Evap fan L T Door switch Cond fan L T Zone temp L T Evap temp If Applicable Cond Fan Compressor Black Programming 42373_C POWER CORD ASSEMBLY 220 240 VOLT PLUG LIVE BLACK 115V BROWN...

Page 28: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Page 29: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Page 30: ...ER 80 54802 00 4 BASKET UPPER 80 54803 00 5 COMPRESSOR ELECTRICALS 80 54800 00 6 COMPRESSOR 80 54799 00 7 CONDENSER ASSY 80 54801 00 8 CONDENSER FAN BLADE 80 54798 00 9 CONDENSER FAN MOTOR 80 54797 00...

Page 31: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Page 32: ...mely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near ro...

Page 33: ...static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across...

Page 34: ...istance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this tec...

Page 35: ...OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor Displa...

Page 36: ...ger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cycle Pow...

Page 37: ...lay and audible alarms The unit will still maintain internal temperatures and set points SHOWROOM MODE This mode is designed to show units in a display environment When in this mode the only functions...

Page 38: ...nly 32 High temp alarm limit Model 55 only 1 THERMISTOR 1 ZONE This shows the pure thermistor reading with no offsets taken into account 2 THERMISTOR 2 EVAPORATOR This shows the pure thermistor readin...

Page 39: ...number of the specific unit See Model list table 22 LIGHT ALL LED SEGMENTS This will illuminate all the LEDs on the display to ensure they work properly 23 ACTIVATE DEFROST HARVEST Press and hold for...

Page 40: ...the U Line button plug the unit into the appropriate power source 4 When the flashing digits appear 3 5 seconds use the up and down arrow buttons to select the appropriate model number or See Above Mo...

Page 41: ...e operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails the unit...

Page 42: ...hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak refer to the Control Operation Service section and adjust unit to defrost every 9 hours...

Page 43: ...the cooling cycle or if not currently cooling the fan will run for 1 minute to circulate air Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door...

Page 44: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Reviews: