OPERATION
3. OPERATION
Before switching ON the unit, check that the electrical connections have been made correctly and
above all, that the ground connection is available and working properly.
Please read before using this manual
- This manual is part of the product and should be kept near the instrument for easy and
quick reference.
- Digital controller with defrost and fans management shall not be used for purpose different
from those described hereunder. It cannot be used as a safely device.
- Check the application limits before proceeding.
Safety precautions
- Check the supply voltage is correct before connecting the instrument.
- Do not expose to water or moisture: use the controller only within the operating limits
avoiding the temperature changes with high atmospheric humidity to prevent formation of
condensation.
Warning
- Disconnect all the electrical connections before any kind of maintenance.
- In case of failure or faulty operation contact technical service or Dealer.
- Consider the maximum current which can be applied to each relay.
- Ensure that the wired for probes, loads and the power supply are separated and far enough
from each other, without crossing or intertwining.
3.1 CONTROLLER GENERAL DESCRIPTION
The controller is a microprocessor based controller suitable for normal
and low temperature air- ventilated application with a membrane
keyboard. The controller has dimensions 101 x 67 x 47 mm, while the
keyboard has dimensions 200 x 82 millimeters, six electro-mechanical
relays.
The controller is also provided with 2 probe inputs either NTC or PTC
type: the probe “
Pb1
” defined as “
Control probe”
and used for the
compressor activation, the “
Pb2”
defined as “
Evaporator probe”
and used to control the evaporator
fan operation and the defrost cycle; The device has also an additional input configurable as
analogue input (“
Auxiliary probe”
Pb3
) or digital input (“
Door switch/multi-function input”)
Technical Data
Heat and fire resistance category:
D.
Connections:
Removable screw terminal blocks for wires up to 2,5 mm
2
; Micro-MaTch
connectors; Pico-blade connectors.
Maximum length allowed to the connection cables:
10 meters (32,8ft) for power supply cord;
10 meters (32,8ft) for Analogue inputs; 10 meters (32,8ft) for Digital inputs; 10 meters (32,8ft) for
Digital outputs.
Operating temperature:
from -5°C to 55°C (from 23 to 131°F)
Operating humidity:
Relative humidity without condensate from 10 to 90%.
Pollution status of the device:
2.
16
Use and Operational Manual
16
Summary of Contents for UCFZ527-SS31A
Page 25: ...OPERATION 3 3 14 Electrical connection 22 Use and Operational Manual 22...
Page 26: ...OPERATION 3 3 15 Default parameters value and description 23 Use and Operational Manual 23...
Page 27: ...OPERATION 24 Use and Operational Manual 24...
Page 28: ...OPERATION 25...
Page 29: ...OPERATION 26 26...
Page 30: ...OPERATION 27 Use and Operational Manual 27...
Page 31: ...OPERATION 28 Use and Operational Manual 28...
Page 54: ...51 FUNCTIONNEMENT 3 3 14 Connexion lectrique 90 Use and Operational Manual...
Page 56: ...53 FUNCTIONNEMENT 92 Use and Operational Manual...
Page 57: ...FUNCTIONNEMENT 54...
Page 58: ...55 FUNCTIONNEMENT...
Page 59: ...FUNCTIONNEMENT 56...
Page 60: ...57 FUNCTIONNEMENT...