USER GUIDE
u-line.com
Quick Guide
GENERAL BOARD FUNCTIONS
PROGRAM AN UNPROGRAMMED BOARD
THERMISTOR RESISTANCE DATA
ON/OFF
Press power button and unit will turn on or off.
Light
Hold the Down key and Light key. Adjust between settings 0, 1, or 2. Tap Light key to save.
Change F/C
Hold Up and Down buttons for 5 seconds.
Showroom Mode
Hold Light and Power buttons for 5 seconds to enter. Unplug to exit. The degree symbol will flash
while in Showroom mode.
Sabbath Mode
Hold Light button for 5 seconds to enter. Tap Light button to exit.
Service Mode
Hold down Hidden button (U-Line logo) to enter. Scroll through options with Up and Down buttons.
3 Hour Shutoff Mode
(Silent Mode)
Hold Down button and Power button for 5 seconds to enter Silent Mode on select models.
Clean Mode
Hold the Clean button for 5 seconds to enter Clean mode on select models.
1. Plug the unit into appropriate power source as defined
on the data plate.
2. Once the double dashes appear, hold the hidden
U-Line button for 3-5 seconds.
3. When 00 appears, use the up and down buttons to
select the appropriate model number.
4. Press the light bulb button once.
5. The display will blink, and then will appear as the
programmed display.
To set a programmed board to the correct model, see
“Programming the Unit to Correct Model Number” in
the “Control Operation-Service” section.
TEMP (F)
TEMP (C)
Nominal
Resistance
(OHMS)*
-40
-40
169157
-31
-35
121795
-22
-30
88766
-13
-25
65333
-4
-20
48614
5
-15
36503
14
-10
27681
23
-5
21166
32
0
16330
41
5
12696
50
10
9951
59
15
7855
68
20
6246
77
25
5000
86
30
4029
95
35
3266
104
40
2665
113
45
2186
122
50
1803
131
55
1495
140
60
1247
149
65
1044
158
70
879
167
75
743
176
80
631
* + 5%
29