REED SWITCH
A reed switch is used to monitor door state. When the
door is closed magnetic force pulls the reed to its contact
and closes the circuit which turns the light and display off.
When the door is open the reed pulls away from the
contact and opens the circuit. If the door is left open for
longer than 5 minutes, the switch will trigger an error code
and set an audible warning.
AIR FLOW
NOTICE
The unit requires proper air flow to perform at
its highest efficiency. Do not block the front
grille, internal fans or vents at any time, or the
unit will not perform as expected. Do not install
the unit behind a door.
Quick Chill
CAUTION
!
Quick chill is designed to quickly pull warm
beverages and foods down to optimum storage
temperature. It is important to only initiate
quick chill modes when the unit has been fully
loaded with warm product.
To initiate quick chill:
1. Press to select the desired mode setting.
2. Press
until the temperature set point reads “Quick”.
The quick chill feature will then begin for the period of
time dictated by the mode type. To cancel quick chill
simply select a set point other then “quick”.
Magnet Close To Switch
(Door Closed)
(Switch Closed)
Magnet Away From Switch
(Door Open)
(Switch Open)
Door Removed For Illustration Purposes
Internal Air Flow And Unit Ventilation Diagram