Sabbath Mode

U-Line Clear Ice Machine models are Star-K certified and
can be used during the Sabbath. View a full list of Star-K
certified U-Line units at www.star-k.org.

To prepare the unit for the Sabbath:

1. Press

 and hold the until the unit turns off.

2. No new ice will form when the unit is off, but previously

made ice will still be accessible/present for over 24
hours. Pump equipped models will continue to remove
water as needed even if the unit is off.

Sabbath Mode remains active until   is pressed again 
and the unit turns on.

1

2

3

4

5

6

Up

Select

Down

33

Summary of Contents for U-3045CLRS-00A

Page 1: ...USER GUIDE SERVICE MANUAL Model U 3045CLRS 00A...

Page 2: ...eral Installation Integrated Grille Dimensions Grille Plinth Installation Door Swing Door Stop Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Con...

Page 3: ...54 0300 Service Email onlineservice u line com Parts Email onlineparts u line com GENERAL INQUIRIES U Line Corporation 8900 N 55th Street Milwaukee Wisconsin 53223 USA Monday Friday 8 00 am to 4 30 pm...

Page 4: ...precautions with those listed throughout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or...

Page 5: ...stall or operate the unit behind closed doors Be sure front grille plinth strip base fascia is free of obstruction Obstructing free airflow can cause the unit to malfunction and will void the warranty...

Page 6: ...r take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations re...

Page 7: ...and 90 F 32 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct su...

Page 8: ...dry If the detachable type electric supply cord is damaged it must be replaced by an equivalent cord available from the manufacturer or its service agent NOTICE Electrical installation must observe a...

Page 9: ...increase the overall cutout width for ease of installation The Modular 3000 Series units are engineered with a variety of adjustment features to help ensure a seamless installation Adjustable doors l...

Page 10: ...mensions 1 SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions Not Including Handle 24 610 mm 33 11 16 to 34 11 16 856 mm to 881 mm 17 3 4 450 mm 3 5 8 to 4 5...

Page 11: ...ensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4...

Page 12: ...safely and properly install this product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes be...

Page 13: ...ts other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to th...

Page 14: ...y damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened...

Page 15: ...tall a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump NOTICE The maximum lift for the P60 drain pump is 10 feet This...

Page 16: ...a 2 Phillips head screwdriver 3 Completely slide the unit into its position in the cabinet Be certain unit height is properly adjusted See GENERAL INSTALLATION 4 Open door completely Make certain door...

Page 17: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 5 Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into cabinetry frame using the anti tip bracket as a template 6 Install the 3 remaining 8...

Page 18: ...mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the front legs to level the uni...

Page 19: ...your grille plinth strip base fascia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish applicatio...

Page 20: ...p base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fascia in...

Page 21: ...the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clea...

Page 22: ...imately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should slide...

Page 23: ...re that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This wou...

Page 24: ...ment and Adjustment Procedure 1 Using a T 25 Torx Bit loosen each pair of Torx head screws on both the upper and lower hinge plates 2 Square and align door as necessary 3 Tighten Torx head screws on h...

Page 25: ...irst two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin operating under the factory default setting Follow the on...

Page 26: ...4 To exit press or simply wait for the menu to time out CUSTOMER MENU The 3000 Series of U Line undercounter refrigeration appliances contains a feature rich customer menu The Customer Menu allows ac...

Page 27: ...the Customer Menu press and select Return to Menu Energy Saver Mode Energy Saver mode reduces overall energy consumption by reducing the amount of ice stored in the bin along with decreasing the ligh...

Page 28: ...Off To select a new tone level enter the Sound Level Menu from the Customer Menu 1 Press or to select the current sound level 2 Press The current setting will begin to flash 3 Press or to select a dif...

Page 29: ...ete After 3 hours in Silent Mode normal ice production will continue NOTE Silent Mode will not silence any alerts To initiate Silent Mode enter Silent Mode Menu from within the Customer Menu To activa...

Page 30: ...S MAINTENANCE SERVICE Help To access the Help Menu select Help from the Customer Menu Press or to scroll through available information To return to the Customer Menu press to select Return to Menu and...

Page 31: ...n an ice bridge of approximately 1 16 to 1 8 1 6 mm to 3 2 mm under normal conditions resulting in a dimple of approximately 1 4 to 1 2 6 4 mm to 12 7 mm in depth A fuller cube with less of a dimple r...

Page 32: ...ust ice thickness as follows 1 Press and hold for 5 seconds to enter the Customer Menu 2 Press to select Ice Adjust 3 Press The selection will begin to flash 4 Press to make the ice thicker or to make...

Page 33: ...certified U Line units at www star k org To prepare the unit for the Sabbath 1 Press and hold the until the unit turns off 2 No new ice will form when the unit is off but previously made ice will sti...

Page 34: ...OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the un...

Page 35: ...the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean int...

Page 36: ...ay result 1 Switch the ice maker off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove the standpipe by lifting it up while using...

Page 37: ...flows over the evaporator assembly ice mold Initially the water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will corr...

Page 38: ...y Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any type of clea...

Page 39: ...ines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures o...

Page 40: ...tion of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evap...

Page 41: ...of any dirt or lint buildup Water in Bin Ensure the unit is plugged in Check if the drain is restricted Ensure drain is free of foreign debris and hose is not kinked or twisted Hear Running Water Dur...

Page 42: ...UTRAL WHITE 115V BLUE 220 240V NEUTRAL WHITE 115V LIGHT BLUE 220 240V NEUTRAL HOT BLACK 115V BROWN 220 240V BLACK W YELLOW 115V BLACK W YELLOW 220 240V HOT HOT BLACK 115V BROWN 220 240V 115 VOLT PLUG...

Page 43: ...a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of...

Page 44: ...12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may submitt...

Page 45: ...l be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line r...

Page 46: ...r than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room te...

Page 47: ...o an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run w...

Page 48: ...e diagnostic tips and as always if additional help is required please contact the U Line Corp Customer Care Facility at 1 414 354 0300 for assistance NORMAL OPERATING SOUNDS All models incorporate rig...

Page 49: ...unit if needed Low Ice Production Dirty evaporator dirty condenser faulty bin thermistor Clean the evaporator using U Line cleaner clean the condenser coil if needed check bin thermistor reading in s...

Page 50: ...l Warm near room temperature Hot Warm Warm Extremely cold near inlet outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal in vacuum Warm near room temperature...

Page 51: ...oor Is the UI Now Functional Replace Main Board Replace Reed Switch Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Reed Switch Operating Properly Is the door open The Display w...

Page 52: ...lear the error log press to select Clear Errors and press to confirm The refrigerant vapor leaving the evaporator travels through the suction line to the compressor inlet The compressor takes the low...

Page 53: ...RATURES AND OTHER FEATURES TOUCH AND HOLD TO EXIT SHOWROOM MODE SCROLL DOWN TO EXIT TOUCH AND RELEASE TO EXIT SERVICE MODE CONFIGURES THE ON BOARD USB PORT FOR FLASH DRIVE OR PC LINK DISPLAYS THE NUMB...

Page 54: ...n to the display Unplug the communication cable from the user interface Check the black to red conductors looking for 5 VDC If voltage is present replace the user interface If no voltage is present ch...

Page 55: ...Select to exit Relay Toggle Relay toggle is used to manually switch the state of each relay to test for proper operation In addition to the AC relays DC outputs may also be toggled Relay toggle can a...

Page 56: ...through available information To exit the Input Status menu use Up to select Return to Menu and press Select to confirm Outputs Outputs is used to monitor the state of DC outputs To access Outputs 1 U...

Page 57: ...setting To exit the Offset menu use Up to select Return to Menu and press Select to confirm Self Test Self test is used to initiate a self diagnostic report Any system faults will be displayed under...

Page 58: ...Select to confirm Re Select Model NOTICE Before altering model selection U Line customer service must be notified Failure to notify customer service will result in voiding of the manufacturer warrant...

Page 59: ...he drive Data is recorded in one second increments and is only limited by the capacity of the flash disk The system will create a file named uline csv on the flash disk In the event the file already e...

Page 60: ...Showroom Mode Showroom displays a number of features and allows the unit to be powered on without running the cooling system To toggle showroom mode 1 Use Down to select Showroom Mode 2 Press Select 3...

Page 61: ...t Celsius F C Defrost Duration Minutes 0 Next Defrost Hours 0 Thermistor Four OFFSET 0 Thermistor Three OFFSET 0 Thermistor Two OFFSET 4 Thermistor One OFFSET 0 Thermistor One Differential Up 0 Thermi...

Page 62: ...n an ice water bath they should OHM out at 16 5k 5 The liquid line thermistor is a type two thermistor At 77 it should OHM out at 10k OHMS 5 Thermistor connections must be kept clean A thermistor conn...

Page 63: ...USER GUIDE Defrost 1 SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These models have no defrost options 63...

Page 64: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...