Electrical

WARNING

!

SHOCK HAZARD — Electrical Grounding 
Required. Never attempt to repair or perform 
maintenance on the unit until the electricity has 
been disconnected.

Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.

Altering, cutting or removing power cord, 
removing power plug, or direct wiring can cause 
serious injury, fire, loss of property and/or life, 
and will void the warranty.

Never use an extension cord to connect power to 
the unit.

Always keep your working area dry.

NOTICE

Electrical installation must observe all state and 
local codes. This unit requires connection to a 
grounded (three-prong), polarized receptacle 
that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A power supply (normal household current). An 
individual, properly grounded branch circuit or circuit 
breaker is recommended. A GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
it could be prone to nuisance tripping. However, be sure 
to consult your local codes.

Water Hookup

PREPARE PLUMBING

Please use the braided stainless steel water supply line 
which comes attached. The water line is fitted with a 
standard 1/4" (6.35 mm) compression fitting.

WARNING

!

Prior to installation, determine if this product 
contains a gravity style drain or factory installed 
drain pump. Products without a drain pump may 
only use a gravity style drain. Failure to connect 
water supply or drain line connections properly 
may result in water leakage, personal injury, 
and/or property damage. Disconnect power and 
turn off water to the unit before attempting to 
alter these connections. These connections are 
the responsibility of the owner and must be 
connected per local plumbing code. If you are 
uncertain of how to safely and properly install 
this product, contact a licensed plumber. 

Water Supply Connection

CAUTION

!

Review, obey, and understand the local 
plumbing codes before you install your unit. 
Connect to the cold water supply. The water 
pressure should be between 20 and 120 psi (138 
and 827 kPa). The water line MUST have a shut-
off valve on the supply line.

Summary of Contents for U-3018CLRS-00B

Page 1: ...QUICK START GUIDE Modular 3000 Series 3018 CLR 115 V 60 Hz...

Page 2: ...to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all availab...

Page 3: ...1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 5 Drain 7 Door Swing 8 General Installation 8 Integrated Panel Installation 10 Control Quick Guide 10 First U...

Page 4: ...Looking for more information Visit u line com to view detailed User Guides for all U Line products Clear Ice Machines U 3018CLRS 00B U 3018CLRS 40B U 3018CLRINT 00B U 3018CLRINT 40B Visit http www u...

Page 5: ...o follow this safety statement may result in minor or moderate personal injury property or equipment damage Environmental Requirements This model is intended for indoor interior applications only and...

Page 6: ...appliances and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup PREPARE PLUMBING Please use the braided stainles...

Page 7: ...r harm flooding or void the product warranty CAUTION Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn off water supply and disconnect electrical supply to pr...

Page 8: ...be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all co...

Page 9: ...r unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump NOTICE The maximum lift for the P60 drain pump is 10 feet This must be done as close to the...

Page 10: ...itional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for...

Page 11: ...opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back an...

Page 12: ...t all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed 8 Locate 6 of the 6x 1 1 2 38 mm screws provided with your unit 9 Using a Phillips...

Page 13: ...ESS ADJUSTMENT NOTICE Ice thickness adjustment should only be made one increment at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness Ice is produced in layer...

Page 14: ...imately 15 20 minutes at the default cube thickness 0 Your clear ice machine is pre set to produce ice between the optimal dimensions illustrated below ICE ADJUST Adjust ice thickness as follows 1 Pre...

Page 15: ...l 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall...

Page 16: ...s of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from...

Reviews: