Installation Guide
11
Ice Machines
9
Leveling Information
It is recommended that the unit is level once installed.
6. Use a level to check the
levelness of the unit from
front to back and from side
to side. Level should be
placed along top edge and
side edge as shown.
7. If the unit is not level, remove grille and adjust feet as necessary.
Use included tool to adjust the height of the rear leveler feet. Turn
screw clockwise to raise the rear foot, counter-clockwise to lower.
8. Check the levelness after each adjustment and repeat the previous
steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cut-out opening,
adjust the rear feet to achieve a total unit rear height of 1/8" less than
the opening’s rear height. Shorten the unit height in the front by
adjusting the front feet. This allows the unit to be gently tipped into
the opening. Adjust the front feet to level the unit after it is correctly
positioned in the opening.
Installation
1. Plug in the power cord.
2. Gently push the unit into position. Be careful to not entangle the
electrical cord, water line and drain line.
3. Re-check the leveling, from front to back and side to side. Make
any necessary adjustments. The unit’s top surface should be
approximately 1/8" below the countertop.
4. Install the 6 cabinet mounting screws for the Anti-tip bracket.
5. Remove the tape from the glass shelves and wipe out the inside of
the unit with a clean, water-dampened cloth.
Installation Troubleshooting
Problem
Q:
The door remains open unless it is pushed closed.
Solution
A:
The hinges should be self-closing when the door is open
approximately 8". If this is not the case, make sure nothing is caught
in the hinge closing mechanism. Also, re-check leveling from front to
back of the unit and readjust if necessary. Make sure that pivot plate
is installed correctly.
Problem
Q:
The custom overlay door was designed to align with the rest of the
cabinet doors, but the unit has crept forward.
Solution
A:
Make sure that the electrical cord, water supply line or drain line is
not obstructing the installation.
9 Level & Install
2
1
Rotate Clockwise to raise rear leg.
Rotate Counter-Clockwise to lower leg.
Rotate Forward Feet to Adjust