background image

USER GUIDE

Integrated Panel Dimensions 2

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

HANDLELESS INTEGRATED FRAME

The following procedure is designed to provide a finished, 
handleless frame for an 18" (45 mm) door that seamlessly 
integrates with its surrounding cabinetry.

NOTE: Many cabinet manufacturers provide a ready 
solution for a handleless, integrated design that can be 
easily applied to your U-Line 3000 Series model. Consult 
your cabinet manufacturer for applicable design and 
installation details. The cabinet manufacturer’s solution to 
this design and integration detail will often result in an 
integrated frame solution wherein the size of the frame 
may result in a height dimension taller than what we 
specify. This can be achieved provided the additional 
height is positioned above the appliance door.

NOTICE

The integrated frame aligns with the 
surrounding cabinetry and, due to differences in 
cabinetry, may not align perfectly with the door.

The appliance will need up to 34-1/2" (876 mm) 
to the underside of the counter to leave room for 
leveling adjustments.

A single prepared frame with insert must not 
weigh more than 20 lbs (10 kg).

Integrated Frame Preparation

1. Cut the main panel to the dimensions below. For

details, see the drawings on the next page.

2. Create the top design for the handleless feature and

the 1/8" (3 mm) notch for the insert(s) indicated on
the appropriate Top Detail drawing, on the next page.

3. Prepare the insert(s) that will back up the handleless

design. 

Wooden Insert

 – Cut 1/8" (3 mm) thick

wooden insert(s) to the appropriate dimensions below.

4. Optional: Stain or finish frame and wooden insert to

desired stain or color. Be sure to closely follow the
instructions provided by the manufacturer.

NOTICE

If finishing panel or wooden insert, all sides 
must be finished to prevent warping.

5. Attach the insert to the frame. Wood glue or equivalent

adhesive should be used to attach insert to frame.

Main panel width

Main panel height

17-5/8" (445 mm)

28-13/16" (732 mm)

Wooden insert width

Wooden insert height

17-5/8" (445 mm)

3-1/2" (89 mm)

Cutout

Integrated Frame

Main Panel

Wooden Insert

Top Design
and Insert Notch

Attach Wooden Insert

5

Summary of Contents for U-2218RGLINT-00A

Page 1: ...USER GUIDE SERVICE MANUAL Model U 2218RGLINT 00A...

Page 2: ...SERVICE MANUAL Table of Contents Click on any section below to jump directly there Installation Integrated Panel Dimensions Integrated Panel Installation Integrated Grille Dimensions Grille Plinth In...

Page 3: ...ldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Produ...

Page 4: ...10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in th...

Page 5: ...pliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared frame with insert must not weigh more than 20 lbs 10 kg Integrated Frame...

Page 6: ...Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Top Detail Insert...

Page 7: ...sions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional I...

Page 8: ...nel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integrated F...

Page 9: ...egrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT INTEGRATED FRAME FLAT AND WITHOUT INTERFERENCE...

Page 10: ...to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish application and cure times 3 Apply double sided tape...

Page 11: ...oor using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door If using tape be certain the tape will not damage panel finish upon removal 7 Us...

Page 12: ...sh against the bottom of the channel 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten sc...

Page 13: ...a When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille plinth st...

Reviews: