Section 3 - Service and Repair
LIMIT SWITCH SPECIFICATIONS
• Normally closed Bi-metal switch
• Open temperature: 104°F
• Close temperature: 83°F
The function of this switch is to open in the event of an
overheating condition. This bi-metal thermostat is normally
closed and does not initiate the ice harvest cycle. The ice
harvest cycle is initiated by a double throw, single pole
temperature located remotely from the ice maker assembly.
Figure 12. Limit Switch
28.12
3.00
183-10