background image

PAGE 3 OF 6 

1018 IH-7357

STORAGE

CHARGING INSTRUCTIONS

OPERATION

•  Charge battery every three to six months in storage 

to keep the internal battery fully charged to prolong 

the overall battery life.

•  Avoid storing in direct sunlight, in extreme heat or 

cold, and wet or damp areas.

•  It is recommended to keep this unit indoors when 

outside temperature is below 32°F.

•  Always store battery clamps attached to the posts 

on the unit and accessories properly within the jump 

starter.

IMPORTANT! Charge immediately after 
purchase, after each use and every three 
to six months. Only use the charging cables 
provided with the unit.

•  Keeping the internal battery fully charged will help 

to prolong the overall battery life.

•  Always disconnect and store charging accessories 

properly within the jump starter case.

•  AC charging cable and DC charging cable are 

included with unit.

 

•   AC charging cable: Connect the AC plug to the 

unit, then connect the charger to a grounded AC 

electrical outlet. The charger is now activated.

 

•   DC charging cable: Connect the DC plug to the 

unit, then plug the 12 volt adapter into the DC 

socket or the car. The charger is now activated.

TURNING JUMP STARTER ON/OFF

•  Press the power button for three seconds to switch 

on the device.

•  Press the power button for three seconds to switch 

off the device.

USING LED LIGHT

•  Activate power button on the jump starter.

•  The light works in the following sequence by pressing 

the switch:

 

•  Press light button once – flashing white light.

 

•  Press light button twice – steady white light.

 

•  Press light button third time – turns off light.

USING USB PORTS

•  The two USB ports provide up to 2.4A at 5V DC.

•  Activate power button on the jump starter power 

pack.

•  Plug USB device into the connector port of the unit.

TEST – VEHICLE BATTERY

•  Make sure the vehicle ignition is turned off, and that 

the engine is not running.

•  Connect clamps to red positive (+) clamp to the 

positive (+) post of battery, then connect the black 

negative (–) clamp to the negative (–) post of battery.

•  Activate power button on the jump starter.

•  Press the test button once to choose battery test 

function ( 

 ); LCD will display vehicle battery voltage 

and its status (low, mid or full).

TEST – VEHICLE ALTERNATOR

NOTE: The vehicle's engine will need to be 
running for this test.

•  Connect the jumpstart red positive (+) clamp to 

the positive (+) post of battery, then connect the 

jumpstart black negative (–) clamp to the negative (–) 

post of battery.

•  Activate power button on the jump starter.

•  Press the test button twice to choose alternator test 

function (   ); LCD will display vehicle alternator 

output voltage and its status (low or full).

Summary of Contents for RESCUE H-7357

Page 1: ...ent to start cars light trucks ATVs boats lawn and garden equipment and other 12V equipment Units feature a 5V USB Unit also features a safety work light that can be set to continuous on or flashing mode LCD display screen provides indication of reserve power level and shows when unit is charged or fully charged Each LCD display will also prompt an error protection code if the unit is incorrectly ...

Page 2: ... intended for use by young people without supervision Do not set the unit on flammable materials such as carpeting upholstery paper cardboard etc Never place the unit directly above battery being jumped WARNING Working in the vicinity of a lead acid battery is dangerous Batteries generate explosive gases during normal battery operation It is important to follow these instructions each time you use...

Page 3: ...tton for three seconds to switch on the device Press the power button for three seconds to switch off the device USING LED LIGHT Activate power button on the jump starter The light works in the following sequence by pressing the switch Press light button once flashing white light Press light button twice steady white light Press light button third time turns off light USING USB PORTS The two USB p...

Page 4: ...t to start the vehicle during Ready cycle NOTE If the LCD display does not show READY and instead shows CONNECTING the battery voltage being detected as less than two volts If this occurs see Override Mode instructions Starting the engine engaging the ignition activates a 10 second start cycle countdown After each starting attempt the unit will cool down for 30 seconds LCD will display the remaini...

Page 5: ...ture on the surface of the battery exceeds 131 F the unit will stop working to prevent damage to the internal battery The error code F03 will display and flash until the unit is cool enough to use again The unit should not operate or be subjected to temperatures at or above 518 F Overload Protection Fault Error Code F04 If a user attempts to start a vehicle s engine whose cranking current is highe...

Page 6: ...t car Clamps are not making a good connection to the battery The unit is not charged The vehicle s battery voltage is over 15V The vehicle does not have a battery The temperature of the jump starter s internal battery is low Check for poor connection to battery Make sure connection points are clean Check the battery charge status and recharge unit if necessary You cannot use this jump starter for ...