background image

QUICK START GUIDE

3

u-line.com

Water Hookup

PREPARE PLUMBING

Please use the braided stainless steel water supply line 
which comes attached. The water line is fitted with a 
standard 1/4" (6.35 mm) compression fitting.

WARNING

!

Prior to installation, determine if this product 
contains a gravity style drain or factory installed 
drain pump. Products without a drain pump may 
only use a gravity style drain. Failure to connect 
water supply or drain line connections properly 
may result in water leakage, personal injury, 
and/or property damage. Disconnect power and 
turn off water to the unit before attempting to 
alter these connections. These connections are 
the responsibility of the owner and must be 
connected per local plumbing code. If you are 
uncertain of how to safely and properly install 
this product, contact a licensed plumber. 

Water Supply Connection

CAUTION

!

Review, obey, and understand the local 
plumbing codes before you install your unit. 
Connect to the cold water supply. The water 
pressure should be between 20 and 120 psi. The 
water line MUST have a shut-off valve on the 
supply line.

CAUTION

!

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use Teflon tape or joint compound on the 
water fitting. The rubber washer provides an 
adequate seal. Other materials could cause 
blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

CAUTION

!

Turn off water supply and disconnect electrical 
supply to unit prior to installation.

1. Turn off water supply and disconnect electrical supply 

to product prior to attempting installation.

2. Locate the desired cold water supply location.

3. Locate braided stainless steel 

water supply line and connect 
to your cold water supply. The 
water line should be looped into 
2 coils. This will allow the unit 
to be removed for cleaning and 
servicing. However, make 
certain that the tubing is not 
pinched or damaged during installation.

4. Turn on water and check for leaks.

Summary of Contents for Modular 3000 Series

Page 1: ...QUICK START GUIDE Modular 3000 Series 3018 CLR 115 V 60 Hz...

Page 2: ...DUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Integrated Panel Instructions Compliance Documentation and Product Warranty informat...

Page 3: ...IDE u line com Contents 1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Water Hookup 4 Drain 6 Door Swing 7 General Installation 8 Control Quick Guide 8 First Use 8 Ice 10 Sabbath Mod...

Page 4: ...sit u line com to view detailed User Guides for all U Line products Clear Ice Machines U 3018CLRS 00A U 3018CLRS 01A U 3018CLRS 40A U 3018CLRS 41A U 3018CLRINT 00A U 3018CLRINT 01A U 3018CLRINT 40A U...

Page 5: ...n serious personal injury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage Environmental Require...

Page 6: ...nect to the cold water supply The water pressure should be between 20 and 120 psi The water line MUST have a shut off valve on the supply line CAUTION Do not use any plastic water supply line The line...

Page 7: ...ck into the ice maker storage bin and or potentially flowing onto the floor which may result in personal injury or property damage NOTICE Drain can NOT be located directly below the unit Unit has a so...

Page 8: ...r does not otherwise meet the requirements for a gravity drain you may have ordered a pre installed U Line P60 drain pump See below for typical installations requiring a drain pump NOTICE The maximum...

Page 9: ...om wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wal...

Page 10: ...ght of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front feet This allows the unit to be gently tipped into the opening Adjust the front feet to...

Page 11: ...at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness Remove all ice from the storage bin Ice cubes in any given batch will vary so it is necessary to choose c...

Page 12: ...e thickness as follows 1 Press and hold for 5 seconds to enter the Customer Menu 2 Press to select Ice Adjust 3 Press The selection will begin to flash 4 Press to make the ice thicker or to make the i...

Page 13: ...a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs performed...

Page 14: ...es of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray fro...

Reviews: