PAGE 11 OF 39
1121 IH-8184
ERROR CODE
DESCRIPTION
CAUSES
RECOMMENDATIONS
E12
One channel have position
different than others.
Too much back drive
occurred.
Move table to fully retracted
position.
Initialize system.
E13
Short circuit detected during
operation.
Squeezed motor cable.
Short in motor.
Check motor cable
connections.
Isolate and replace motor
cable.
Isolate and replace desk
leg.
E15
System has reached its
power limitation.
Power cord pulled during
driving.
Internal fault.
Many times will see this
alongside E10.
Power regulator has
adjusted speed down
on actuators without any
significant current draw,
usually caused by power
supply dropping.
Check mains cable is not
caught, and is allowed to
freely travel.
Use strain-relief loop built
into control box.
E16
Illegal keys pressed
(handled internally in DP1C).
Hitting multiple buttons
simultaneously.
Check desk panel.
E17
LINBUS unit does not support
safety feature.
DP1C/DPF1C does not have
up-to-date software.
Try DP with more recent
software version (printed on
label).
E18
A special service tool is
required to change number
of channels to the system.
Baselift only – Service tool
missing from baselift system
when initializing.
Add service tool.
E23
Channel 1 is detected
missing.
Disconnection.
Faulty motor cable.
Faulty motor in leg.
Check motor cable
connections and Integrity.
Change motor cable or
desk leg.
Initialize the system.
E24
Channel 2 is detected
missing.
Disconnection.
Faulty motor cable.
Faulty motor in leg.
Check motor cable
connections and integrity.
Change motor cable or
desk leg.
Initialize the system.
ERROR CODES CONTINUED