background image

PAGE 1 OF 9 

0221 IH-9045

HARD-WIRED EXIT SIGN

1-800-295-5510

uline.com

H-9045, H-9275

SAFETY

CAUTION! When using electrical equipment, 
always follow basic safety precautions, including:

• Do not use outdoors.
• Do not mount near gas or electric heaters.
• Do not let power cords touch hot surfaces.
•  Use caution when servicing batteries to avoid 

possible shorting.

•  Mount in locations and at heights where it 

will not readily be subjected to tampering by 
unauthorized personnel.

•  Use of accessories not recommended by the 

manufacturer may cause an unsafe condition.

•  Do not use this equipment for anything other 

than intended use.

•  Before wiring to AC service, turn off AC power 

at fuse or circuit breaker.

•  Disconnect AC power and unplug battery 

before servicing.

•  Only use specified lamps in the fixture.

NOTE: Battery in unit may not be fully charged. 

After AC service is supplied to unit, let battery 
charge for at least 24 hours before performing 

any tests.

TOOLS NEEDED

Phillips Screwdriver

Flathead Screwdriver

BACK MOUNTING

1.  Unit comes with EXIT panels on front and back. 

Remove back EXIT panel and replace with back 
plate. Drill 1/4" holes into oblong knock outs on back 
plate that correspond to junction box holes to be 
used. (See Figure 1)

2.  Feed transformer input leads through center hole of 

back plate and make the proper connections.  

(See Figures 2-3) 

NOTE: If using 120VAC, connect black and white 

leads to building utility.

NOTE: If using 277VAC, connect orange and 
white leads to building utility.

NOTE: In some cases, not all leads will be used. 

Cap off unused wire. 

INSTALLATION

Figure 1

Wire Nuts

Oblong Knock Outs

Back Plate

EXIT Panel

Diffuser

Junction

Box

Plastic

Housing

Snap-in

Directional Arrow

120VAC

277VAC

Connect black and white 

leads to building utility.

Connect orange and white 

leads to building utility.

Cap Unused 

Orange Wire

Figure 2

Cap Unused 

Black Wire

Figure 3

Para Español, vea páginas 4-6.

Pour le français, consulter les pages 7-9.

Summary of Contents for H-9045

Page 1: ...it let battery charge for at least 24 hours before performing any tests TOOLS NEEDED Phillips Screwdriver Flathead Screwdriver BACK MOUNTING 1 Unit comes with EXIT panels on front and back Remove back EXIT panel and replace with back plate Drill 1 4 holes into oblong knock outs on back plate that correspond to junction box holes to be used See Figure 1 2 Feed transformer input leads through center...

Page 2: ...ility NOTE In some cases not all leads will be used Cap off unused wire 5 Feed excess wire into junction box and align holes in canopy with holes in crossbar Use screws supplied to tighten canopy to crossbar so canopy is securely fastened and tight against wall See Figure 5 6 Snap in arrows to EXIT panel as required Then snap EXIT panel to housing top first then bottom NOTE Use flexible conduit on...

Page 3: ...canopy into sign at an angle Twist to secure See Figure 9 4 Feed transformer input leads through center hole and make the proper connections See Figures 2 3 NOTE If using 120VAC connect black and white leads to building utility NOTE If using 277VAC connect orange and white leads to building utility NOTE In some cases not all leads will be used Cap off unused wire 5 Feed excess wire into junction b...

Page 4: ...léctrico a la unidad permita que la batería se cargue al menos 24 horas antes de realizar alguna prueba HERRAMIENTAS NECESARIAS Desarmador de Cruz Desarmador Plano INSTALACIÓN POSTERIOR 1 La unidad viene con paneles EXIT por el frente y por detrás Retire el panel EXIT posterior y reemplácelo con la placa posterior Taladre orificios de 1 4 en las entradas alargadas de la placa posterior que corresp...

Page 5: ...as naranjas y blancas a la instalación del edificio NOTA En algunos casos no se utilizarán todas las puntas Bloquee los cables que no utilizará 5 Inserte el excedente de alambre en la caja de conexiones y alinee los orificios con aquellos en la barra transversal Use los tornillos suministrados para ajustar la base a la barra transversal de modo que la base esté bien ajustada contra la pared Vea Di...

Page 6: ...Fije el señalamiento a la base insertando la base en el señalamiento a un ángulo Gire para asegurar Vea Diagrama 9 4 Inserte las puntas de entrada del transformador por el orificio central y realice las conexiones adecuadas Vea Diagramas 2 3 NOTA Si usa 120VAC conecte las puntas negras y blancas a la instalación del edificio NOTA Si usa 277VAC conecte las puntas naranjas y blancas a la instalación...

Page 7: ... CA laissez la batterie se charger pendant au moins 24 heures avant de procéder à des tests OUTILS REQUIS Tournevis cruciforme Tournevis à tête plate FIXATION PAR L ARRIÈRE 1 L enseigne est livrée avec des panneaux EXIT à l avant et à l arrière Retirez le panneau EXIT arrière et remplacez le par la plaque arrière Percez des trous de 1 4 po dans les parties oblongues de la plaque qui correspondent ...

Page 8: ...ures 2 et 3 REMARQUE Si vous utilisez du courant à 120 VCA branchez les fils blanc et noir au réseau électrique REMARQUE Si vous utilisez du courant à 277 VCA branchez les fils orange et blanc au réseau électrique REMARQUE Dans certains cas les fils ne seront pas tous utilisés Recouvrez les fils restants non utilisés d un capuchon 5 Acheminez le surplus de fils dans la boîte de jonction et alignez...

Page 9: ...ne 3 Fixez l enseigne à la hotte en insérant la hotte en biais dans l enseigne Tournez pour fixer Voir Figure 9 4 Acheminez les fils d entrée du transformateur à travers le trou central puis procédez aux branchements adéquats Voir Figures 2 et 3 REMARQUE Si vous utilisez du courant à 120 VCA branchez les fils blanc et noir au réseau électrique REMARQUE Si vous utilisez du courant à 277 VCA branche...

Reviews: