U-Line H-8649 Manual Download Page 8

PAGE 8 OF 10 

0320 IH-8649

OPERATION CONTINUED

SWING OPERATION

When you turn on the unit, the louver will swing and stop 

at a certain angle. You can press the SWING button 

to let the louver swing automatically. Press the SWING 

button again when you want the louver stopped at 

desired angle.

CHECK FILTER FEATURE

This feature is a reminder to clean the air filter (see Care 

and Cleaning) for more efficient operation. The "filter" 

indicator will illuminate after 250 hours of operation. 

To reset after cleaning the filter, press the FILTER RESET 

button and the light will go off.

FAULT CODE

If the display reads "EA," the room 

temperature sensor has failed. Contact 

Uline Customer Service at 1-800-295-5510.

If the display reads "ES," the evaporator 

temperature sensor has failed. Contact 

Uline Customer Service at 1-800-295-5510.

If the display reads "E4," the display 

panel communication has failed. 

Contact Uline Customer Service at 

1-800-295-5510.

If the display reads "P1," bottom tray is 

full. Carefully move the unit to a drain 

location, remove the bottom drain plug 

and let the water drain away. Restart 

the machine until the "P1" symbol  

disappears. If error repeats, call Uline 

Customer Service at 1-800-295-5510.

DRAINAGE

During the dehumidifying mode, you will need a 

garden hose (sold separately) to drain the condensate 

from the unit. Remove the rubber stopper from the hose 

connector. (See Figure 21)

The hose may then:

a.  Discharge into a drain that is lower than the unit.

b.  Be connected to a condensate pump (sold 

separately).

Figure 21

Garden Hose

Remove the 

Supplied 

Rubber Stopper

Summary of Contents for H-8649

Page 1: ... now supplying electricity to the unit NOTE Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power cord must be replaced if it fails to reset when either the TEST button is pushed or if it cannot be reset If power supply cord is damaged it cannot be repaired It must be replaced Contact Uline Customer Service for assistance a...

Page 2: ...ant passing through evaporator during normal operation Vibration Unit may vibrate and make noise because of uneven floor High pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Control Panel Carrying Handle Both Sides Remote Control Room Air Discharge Remote Signal Receiver Exhaust Air Outlet Dehumidifying Drain Outlet Bottom Tray Drain Out...

Page 3: ...e Figure 2 2 Screw the hose onto adapter A See Figure 3 3 Extend the other side of the hose and screw it to adapter B See Figure 4 4 Slide the assembly onto unit See Figure 5 5 Affix adapter B into the window slider kit and seal See Figures 6 and 7 The hose can be extended from its original length of 15 up to 59 but it is the best to keep the length to the minimum required Also make sure that the ...

Page 4: ...crews to secure the window slider kit to the lower sash See Figure 12 5 Secure the window slider kit to the window sill See Figure 12 a For wooden windows use 3 4 screws for securing b For Vinyl Clad windows use 1 2 hex head cap screws for securing 6 To secure lower sill in place attach sash lock with 1 2 screw as shown See Figure 13 NOTE It is difficult to lock vinyl clad windows with the sash so...

Page 5: ...26 6 See Figure 17 3 Close the sliding sash securely against the window slider kit See Figure 18 4 Secure the window slider kit to the window sill See Figure 18 a For wooden windows use 3 4 screws for securing b For Vinyl Clad windows use 1 2 hex head cap screws for securing 5 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash See Figure...

Page 6: ...ay cause undesired operation NOTE The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the keypad so the settings cannot be changed The key symbol will appear in the display of the remote control when locked Depress the LOCK button again to release Use a small pin to depress these buttons Remote Control Screen Display Temperatur...

Page 7: ...ION You can set both delay stop and delay start while unit is in ON or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate Tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours Then press the TIMER button to confirm the settin...

Page 8: ... 1 800 295 5510 If the display reads ES the evaporator temperature sensor has failed Contact Uline Customer Service at 1 800 295 5510 If the display reads E4 the display panel communication has failed Contact Uline Customer Service at 1 800 295 5510 If the display reads P1 bottom tray is full Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Rest...

Page 9: ...ds AIR FILTER CLEANING This unit has two filters filter A and B Grasp the upper panel tab and take off filter A behind the grill of the back panel See Figure 22 Remove the lower filter B by loosening the screws Take down the air inlet grill then remove the air filter See Figures 23 and 24 Wash the filters using liquid dish washing detergent and warm water Rinse filters thoroughly Gently shake exce...

Page 10: ...mperature is set too low for nighttime cooling Exhaust duct not connected or blocked Cooling may not occur until room temperature rises above 60 F 16 C Clean filter Refer to Care and Cleaning section on page 9 To defrost set to fan only mode To defrost the coil set to fan only mode Then set temperature to a higher setting See Exhausting Hot Air section on page 3 Air conditioner cooling but room is...

Reviews: