OPERATION

PLACEMENT OF THE UNIT

There are three primary considerations when deciding 

where to place this unit:

1.  Fresh Air Supply – The inlet side of the unit  

(pad side) must be placed so as to ensure that a 

smooth, uninterrupted supply of fresh air is available.

2.  Air Pattern – The cool air discharged from  

(fan side) the unit should have a clear area in which 

to circulate, being as free of obstructions as  

possible.

3.  Ventilation (Exhaust) – There should be a defined 

place in which the air from unit can be exhausted 

from the area being cooled. This is to prevent the unit 

from recirculating air that has already been through 

the cooling process.

A primary consideration when actually deciding where 

to place the unit is the direction of the airflow. The unit 

creates a fan-shaped air pattern that circulates air over 

a large area. This pattern may be disturbed or broken 

up by obstacles such as shelves, workbenches, etc. It is 

important to insure that a clean, unbroken path for the air 

from the unit is provided to the maximum extent possible.

You may want to raise the unit above any low 

obstructions in order to increase the overall coverage. 

When raising the height, ensure that the platform 

constructed for holding the unit is stable, well constructed 

and will not allow the unit to tip over. The unit must be 

level and in the upright position, with casters locked.  

When supporting with a platform allow for the full weight 

of a functioning unit by including the weight of the water 

both in the sump tank and the added weight of the water 

saturated cooling pads. The total weight could be in 

excess of 500 lbs. (227 kg.).

When the unit is placed near a wall or other obstruction, 

it is recommended that a distance of at least 3 feet from 

any wall or obstruction to the face of the cooling pads. 

This allows the unrestricted flow of warm air to the cooling 

pad side of the unit. If multiple units are used near 

each other, be sure to aim the unit so that the air flows 

compliment each other. Opposition will negate the 

airflow and allow an area of dead air to accumulate 

between units.

FILLING WITH WATER

Once the unit is connected to a water supply, turn on the 

supply valve that fills the sump tank with water. Once the 

sump tank is full, the float valve will shut off the supply 

flow. (50 psi max. inlet water pressure.)

STARTING THE PUMP AND ADJUSTING  

THE WATER FLOW

CAUTION! Do not run pump when sump is dry.

1.  Once the sump tank is full, move the pump switch to 

the ON position to turn on the pump. 

 

When first turning on the pump, the level in the sump 

will drop suddenly and restart the flow of supply 

water. This is a normal condition, as the cooling pads 

require a large amount of water for proper wetting. 

 

When the unit is new, the new pads will require an 

initial 'breaking-in' period. This period is required for 

the pads to begin readily absorbing water. It may 

require up to a week to achieve maximum efficiency.

2.  It is important that the spray bar is properly adjusted 

when first starting the water flow in the unit. To 

increase or decrease the flow use the spray bar 

adjustment valve on the side of the unit.

NOTE: Evaporative media should appear wet.

STARTING THE FAN

NOTE: Cooling pads must be installed and wet, 
and caster brakes must be engaged.

Start the fan by turning the fan switch to desired speed. 

Adjust the speed slowly allowing the fan to obtain its full 

speed at the low speed before going to meidum and 

high.

Pads should appear wet; however, cascading amounts 

of water can actually reduce cooling efficiency. Proper 

adjustment will prevent problems and increase cooling 

capacity.

When turning the fan off at the end of the day or 

week, the pump should be turned off about 15 minutes 

before the fan to allow the cooling pads to dry. This will 

increase the life fo the pads.

Summary of Contents for H-7126

Page 1: ...move the plug from the electrical receptacle by pulling on the plug not the power cord Operation near open flames or sparks is not recommended If operating near open flame or sparks ensure the pump is continuously running in order to saturate and wet evaporative media To prevent damage when cleaning evaporative cooler ensure water does not get into the motor or electrical system The use of extensi...

Page 2: ...l switches Before connecting the plug to an outlet ensure that there is no standing water where the cord may lie or the operator is standing The use of separate multiple outlet devices are not recommended When making electrical connections ensure that local and national codes are adhered to Use only with GFCI protected receptacles Please refer to the barcode product label on the side of the unit f...

Page 3: ... cooling pads This allows the unrestricted flow of warm air to the cooling pad side of the unit If multiple units are used near each other be sure to aim the unit so that the air flows compliment each other Opposition will negate the airflow and allow an area of dead air to accumulate between units FILLING WITH WATER Once the unit is connected to a water supply turn on the supply valve that fills ...

Page 4: ... drained and the power disconnected the pads may be removed for inspection of the sump tank If the unit is in a dusty environment dust may collect in the sump tank over time Vacuum out dirt and any remaining water using a wet dry shop vacuum and wipe clean with a cloth Inspect and clean the inlet strainer located on the bottom of the pump Replace pads in correct airflow direction referring to labe...

Page 5: ...draining from the evaporative cooler Seat in float valve leaking Drain plug not tight Replace float valve Tighten plug Knocking shaking or rattling sounds Loose parts Fan blade rubbing shroud Check and tighten where needed Inspect and adjust or replace fan blade Musty or unpleasant odor Stale or stagnant water in tank Evaporative media is mildewed or clogged Drain flush and clean tank Replace evap...

Page 6: ...the temperature in almost any environment making it more comfortable Q How often should evaporative media be replaced A Depending on the quality of maintenance and frequency of use evaporative media typically last up to five years Q What is the difference between evaporative cooling and misting systems A Misting systems spray a shower of water into the air that will collect on people objects equip...

Page 7: ...ther side of the center pad may then be removed in the same manner To remove the two outside pads first pull them sideways toward the center of the unit until they clear the side retainer They may then be removed in the same manner as the other pads 1 Locate the set screw in the rear of the unit on the upper right side See Figure 1 2 Remove set screw and lower front flap to vertical position 3 Onc...

Page 8: ...es para asegurarse de que funcione adecuadamente Retire el enchufe del recipiente eléctrico jalando del mismo no del cable No se recomienda operarlo cerca de flamas abiertas o chispas Si se operara cerca de flamas abiertas o chispas asegúrese de que la bomba se encuentre en funcionamiento continuo para que el panel se pueda mojar Para prevenir daños cuando limpie el enfriador evaporativo asegúrese...

Page 9: ...nico cable eléctrico e interruptores de control Antes de conectar el enchufe a una toma eléctrica verifique que no haya agua estancada donde el cable se apoyará o donde se pare el operario No se recomienda el uso de múltiples dispositivos independientes de toma eléctrica Al hacer conexiones eléctricas asegúrese de cumplir con los códigos locales y nacionales Para usar solo con receptáculos con pro...

Page 10: ...des una cerca de la otra asegúrese de orientar las unidades de forma que los flujos de aire se complementen unos a otros La oposición obstaculizará el flujo de aire y ocasionará que se acumule una zona de aire muerto entre las unidades RELLENAR CON AGUA Una vez que la unidad esté conectada a un suministro de agua accione la válvula de suministro que llena el tanque del colector del agua Una vez qu...

Page 11: ...ctor Si la unidad está ubicada en un entorno con mucho polvo es posible que el polvo se acumule en el tanque del colector con el paso del tiempo Aspire la suciedad y el agua restante usando una aspiradora en seco mojado y limpie con un paño Inspeccione y limpie el filtro de entrada ubicado en la parte inferior de la bomba Vuelva a colocar los paneles en la dirección correcta del flujo de aire cons...

Page 12: ...r evaporativo El empaque de la válvula del flotador está goteando El tapón del desagüe no está apretado Reemplace la válvula del flotador Apriete el tapón Sonidos de golpes sacudidas o vibraciones Partes sueltas Las aspas raspan con la cubierta Verifique y apriete donde se necesite Inspeccione y ajuste o reemplace las aspas del ventilador Olor rancio o desagradable Agua rancia o estancada en el ta...

Page 13: ...rativos reducirán la temperatura en casi cualquier ambiente volviéndolo más cómodo P Qué tan seguido se debe de reemplazar el panel R Dependiendo de la calidad del mantenimiento y de la frecuencia del uso Los paneles normalmente duran hasta 5 años P Cuál es la diferencia entre un enfriador evaporativo y un sistema de rocío R Los sistemas de rocío proyectan agua al aire que se quedará en las person...

Page 14: ...isma forma Para quitar los dos paneles exteriores primero tire de un lado de ellos hacia el centro de la unidad hasta que se suelten del retenedor lateral Pueden quitarse de la misma forma que el resto de paneles 1 Localice el tornillo de ajuste ubicado en el lado superior derecho de la parte posterior de la unidad Vea Diagrama 1 2 Quite el tornillo de ajuste y baje la solapa delantera hasta coloc...

Page 15: ...tilisation à proximité de flammes nues ou d étincelles n est pas recommandée Si vous travaillez à proximité d une flamme nue ou d étincelles assurez vous que la pompe fonctionne continuellement afin de saturer et d humidifier les milieux d évaporation Pour éviter tout dommage lors du nettoyage du refroidisseur assurez vous que l eau ne pénètre pas dans le moteur ou le circuit électrique L utilisat...

Page 16: ...ition verticale et les tampons de refroidissement en place Cette unité est munie d un seul cordon d alimentation et de commutateurs de commande Avant de brancher la fiche à une prise assurez vous qu il n y a pas d eau stagnante près du cordon ou de l utilisateur L utilisation d une barre multiprise n est pas recommandée Veuillez vous référer à l étiquette code à barres située sur le côté de l appa...

Page 17: ... que les débits d air soient complémentaires Des débits d air qui s opposent auront pour effet de neutraliser la circulation d air en plus de laisser un air stagnant s accumuler entre les unités REMPLISSAGE AVEC DE L EAU Lorsque l unité est raccordée à une alimentation en eau activez la soupape d alimentation qui remplit d eau le réservoir collecteur Dès que le réservoir collecteur est plein le ré...

Page 18: ...e trouve dans un environnement poussiéreux il est possible que de la poussière s accumule dans le réservoir collecteur au fil du temps Aspirez la saleté et l eau restante à l aide d un aspirateur d atelier pour déchets solides et humides et essuyez à l aide d un chiffon Inspectez et nettoyez le filtre d entrée situé au bas de la pompe Replacez les tampons dans le sens du débit d air en vous référa...

Page 19: ...e côté du milieu d évaporation du refroidisseur est trop proche d un mur Panne du moteur du ventilateur Panne du condensateur Déplacez le refroidisseur à au moins trois pieds du mur Remplacez le moteur du ventilateur Remplacez le condensateur L eau s écoule du refroidisseur Le siège du régleur à flotteur fuit Le bouchon de vidange n est pas serré Remplacez le régleur à flotteur Serrez le bouchon P...

Page 20: ...l environnement le rendant ainsi plus confortable Q À quelle fréquence le milieu d évaporation devrait il être remplacé R Selon la qualité de l entretien et la fréquence d utilisation le milieu d évaporation dure généralement jusqu à cinq ans Q Quelle est la différence entre les systèmes de refroidissement par évaporation et les systèmes de brumisation R Les systèmes de brumisation pulvérisent une...

Page 21: ...de la même façon Pour retirer les deux tampons extérieurs tirez les d abord latéralement vers le centre de l unité jusqu à ce qu ils se dégagent de la retenue latérale Ils peuvent ensuite être retirés de la même façon que les autres tampons 1 Repérez la vis de réglage à l arrière de l unité sur le côté supérieur droit Voir Figure 1 2 Retirez la vis de réglage et abaissez le rabat inférieur avant e...

Reviews: