PAGE 1 OF 4
0314 IH-4377
π
H-4377
ROTARY DRUM PUMP
1-800-295-5510
uline.com
IMPORTANT! This pump is made out of polypropylene, PVDF, PTFE, 304 stainless steel and EPDM. Use chemicals
compatible with these materials and follow OSHA guidelines when using this pump, including proper
grounding and protective gear as required. Unit not UL or FM approved.
SPEcIFIcATIONS
OPERATING INSTRUcTIONS
Pump Type
Rotary - Vane
Flow
8 GPM (12 oz / Stroke)
Maximum Fluid Temperature
130°F / 54°C
Bung Adapter
2" Male
Suction Tube Length
40" Maximum
Inlet
1⁄" O.D.
Outlet
1" O.D. Curved Spout
Wetted Parts
PP, PVDF, PTFE, 304SS & EPDM
Maximum Viscosity
1,000 cps
1. Rotate handle clockwise several times to prime. If
unit does not prime after a few turns, pouring some
fluid into pump inlet may help free pump.
2. For siphoning, position handle straight down.
3. To stop siphoning, rotate handle 1/4 turn (leave
handle in horizontal position).
4. After using pump, position handle straight down.
Liquid will drain back into the container.
5. If pump is removed from drum, rinse it thoroughly in
a liquid that is compatible with both the pump and
the fluid being pumped.
6. Regularly check pump and suction tubes for leaks.
Leaks in the suction line or in pump housing will
cause inefficient pumping and loss of prime.
TOOLS NEEDED
1/2" (13 mm) Wrench
Flathead Screwdriver
Pour le français, consulter les pages 3-4.