U-Line H-3934 Manual Download Page 3

PAGE 3 OF 7 

0413 IH-3934

Base Frame Anchor Holes – 

4 pre-drilled base frame 

anchor holes are provided inside the base frame to 

secure the lift to the floor or installation surface.

Tools Required

•  Banding or Strap Cutters

•  Drill with 1/2" concrete drill

•  3/4" closed end wrench

DANGER! The lift's electrical circuits use 
voltages which can cause SEVERE PERSONAL 
INJURY or DEATH. 

1.  Using a forklift or similar equipment, move the 

palletized lift to the location it is to be installed. The 

installation area should be clean and have good 

general lighting.

2.  Next, using the strap cutter, remove the bands 

securing the lift to the pallet. Remove all packing 

material and place it off to the side.

3.  Locate a separate box that contains the hand 

control. This box is located under the primary 

packaging material at the end of the base frame. 

Remove the hand control with the control cord from 

the box. Next, insert the control cord disconnect 

plug into the mating receptacle at the end of the 

base frame. Ensure the plug is fully connected and 

the locking tabs are positioned over the posts on the 

disconnect receptacle

4.  Locate the power cord attached to the lift’s base 

frame. All lifts are supplied with a power cord 

plug for use with a conventional 115 volt (20 amp) 

receptacle. Ensure the receptacle to be used is 

rated for 115 volt, 20 amp operation. Insert the plug 

into the receptacle.

 

5.  Using the hand control, depress the UP button to 

raise the lift to its maximum raised height. Following 

the maintenance bar operating instructions, (See 

Page 5) rotate the maintenance bars into the 

maintenance position. 

CAUTION! DO NOT lower the lift to engage the 

maintenance bars at this time.

6.  Using a forklift, position the forks under the platform 

structure. (See Figure 2) Lift the lift table off the pallet. 

Next, remove the pallet and place if off to the side. 

Position the lift in the desired location. Use care not 

to damage the lift’s power cord or control cord. 

 

 NOTE: The base frame must be secured to the 

floor for maximum stability. Contact ULINE 

Customer Service if you have any questions 

regarding the proper installation of the lift. 

Complete steps 7 and 8 to secure lift to the floor.  

7.  Inside the base frame are four 5/8" holes for bolting 

the unit securely to the floor. Using the 4 holes as a 

template, drill a 1/2" diameter hole to a 3" minimum 

depth at each location. The floor surface should be 

level and the drilled holes perpendicular to the floor. 

If required, shift the position of the lift with a forklift 

to allow room for drilling, then drill. When complete, 

reposition the lift.

8.  Prepare the 1/2" diameter x 4

long anchor bolts 

(USE type SUP-R-STUD #26-12400 or equivalent) by 

assembling the washer and nut on the anchor bolt. 

(See Figure 3) The nut should be screwed onto the 

anchor bolt approximately 1/2 the nut height. Drive 

the assembled anchor through the mounting hole 

into the concrete until the washer is flush with the top 

of the anchor plate. Expand the anchor shield by 

tightening the nut 3 to 5 turns. Repeat step 8 for the 

remaining anchors. 

NOTE: Make sure the underside of the base 
frame surface is fully supported with shims  

or concrete grout.

INSTALLATION INSTRUCTIONS CONTINUED

Figure 2

Figure 3

Summary of Contents for H-3934

Page 1: ...letely support the base frame could result in damage to the lift 4 DO NOT use the lift table with an unstable unbalanced or loosely stacked load Unbalanced loads may become unstable and fall SEVERE PE...

Page 2: ...uthorized modifications to this lift table its hydraulic power unit or its control system may compromise the performance and safety of the system UNDER NO CIRCUMSTANCES should you attempt any repair o...

Page 3: ...r operating instructions See Page 5 rotate the maintenance bars into the maintenance position CAUTION DO NOT lower the lift to engage the maintenance bars at this time 6 Using a forklift position the...

Page 4: ...acity of the lift Refer to the capacity decal on the end of the lift platform 2 If required raise the platform to a convenient working height 3 Uniformly distribute the load over the platform or suppo...

Page 5: ...t the maintenance bars 4 Release the DOWN button ALWAYS check the position of both maintenance bars before going under the platform or servicing the lift DISENGAGE THE MAINTENANCE BARS 1 Depress the U...

Page 6: ...t shaped object into the top of the reservoir opening Reinstall the reservoir breather 9 Finally raise the lift and disengage the maintenance bars by returning them to their stored position CHANGING T...

Page 7: ...en Fill reservoir Reduce load Check lower control for malfunction Clean and or replace lowering solenoid Platform will not remain elevated Lower valve held open Pump check valve not seated Check lower...