PAGE 3 OF 6
0514 IH-3069
mAINTENANCE
SPECIfICATIONS
• Always disconnect the tool from the air supply,
empty the magazine and read the safety warnings
before starting maintenance.
• Check that all safety devices function properly,
especially that the trigger moves freely and that all
screws and nuts are securely tightened.
• This tool does not require special servicing. It
only needs regular cleaning with a non-corrosive
cleaning agent. Do not remove any parts for
cleaning purposes.
• A small amount of lubricating oil is needed in the
nipple each day or 10 drops once a week to ensure
safe functioning.
• At high frequency stapling lubricating oil is
recommended.
• Contact Uline for more information: 1-800-295-5510.
mfg. PART NO.
hEIghT
lENgTh
WIdTh
WEIghT
STAPlES
lENgTh
mAgAzINE
CAPACITy
JK20T777L
250mm
375mm
68mm
2,1kg
777
8–16mm
100
• Air pressure:
- Approx. 5-6 bar working pressure
- 7 bar maximum air pressure
• The stapler is designed for use with original Josef
Kihlberg staples only
• Magazine loading: Loaded from above
• Firing of the stapler: Single shot firing
• Air consumption per shot. :0,3 l at 6 bar operating
pressure
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
1-800-295-5510
uline.com