0514 IH-3069

mAINTENANCE

SPECIfICATIONS

•  Always disconnect the tool from the air supply, 

empty the magazine and read the safety warnings 

before starting maintenance.

•  Check that all safety devices function properly, 

especially that the trigger moves freely and that all 

screws and nuts are securely tightened.

•  This tool does not require special servicing. It 

only needs regular cleaning with a non-corrosive 

cleaning agent. Do not remove any parts for 

cleaning purposes.

•  A small amount of lubricating oil is needed in the 

nipple each day or 10 drops once a week to ensure 

safe functioning. 

•  At high frequency stapling lubricating oil is 

recommended. 

•  Contact Uline for more information: 1-800-295-5510.

mfg. PART NO.

hEIghT

lENgTh

WIdTh

WEIghT

STAPlES

lENgTh

mAgAzINE 

CAPACITy

JK20T777L 

250mm

375mm

68mm

2,1kg

777

8–16mm

100

•  Air pressure:  

- Approx. 5-6 bar working pressure 

- 7 bar maximum air pressure

•  The stapler is designed for use with original Josef 

Kihlberg staples only

•  Magazine loading: Loaded from above

•  Firing of the stapler: Single shot firing

•  Air consumption per shot. :0,3 l at 6 bar operating 

pressure