PAGE 3 OF 9
0521 IH-2378
TROUBLESHOOTING
OPERATING INSTRUCTIONS CONTINUED
Model
AIE – 1818L
Max seal length
18" x 18"
Max Seal Thickness
100 ga shrink film
Max Circum
36"
Voltage
110V
Watts
1000 w
Weight
54 lbs
Dimensions
27" x 21.75" x 7.25"
HELPFUL INFORMATION
1. Always keep the sealing platform clean. Particular
care should be taken to remove any residue from
the Teflon
®
tape.
2. Do not clean the sealing platform with anything wet
while sealing machine is plugged into outlet.
3. It is important to replace the element wire with the
one designed for this machine. Using different wires
can damage the transformer.
4. Occasionally check the condition of the upper
silicone rubber pads for wear or burns. A poor
silicone rubber pad will affect the quality of the seal.
SPECIFICATIONS
OPERATING ISSUE
RECOMMENDATIONS
Sealer is not sealing.
Check if the power switch is turned ON.
Check if the fuse is blown. Fuse is located on the back
of unit, left of the power cord. Unscrew the black cap to
reveal the fuse (15 amp). Check fuse with fuse tester or
multimeter. Replace fuse if bad.
If the lamp indicator light is functioning:
• The timer might be faulty. Contact Uline Customer
Service at 1-800-295-5510.
• The element (heating wire) is broken. Refer to
replacement instructions on previous page.
If the lamp indicator is not functioning:
• Check if the power switch is on.
• Check if fuse is blown. See instructions above.
The film is not cutting through.
Check if the upper silicone rubber and the sealing
element are parallel with each other.
1-800-295-5510