background image

PAGE 2 OF 3 

0814 IH-2895

4. Align the indent inside the 

tip of the motor assembly/

bottle support (7) with the 

indent on the shank of the 

dispenser assembly (1) 

and firmly push the motor 

assembly/bottle support up, 

onto the shank.

notE: Hold the data cable (6) out of the way 
as you push up on the motor assembly/bottle 
support. continue pushing upward until the 
vertical slots in the dispenser shank and the 
motor assembly/bottle support line up.

5. secure the motor assembly/

bottle support (7) to the 

dispenser assembly (1) shank 

by pushing the retaining clip 

(5) into place through the 

vertical slots, until it goes all 

the way through the motor 

assembly.

notE: the clip may be inserted from either side.

6. remove the cover from the 

battery box (8) by loosening 

the two captive screws on the 

battery box cover. Position the 

box on a convenient (vertical 

or horizontal) surface under 

the counter top that will allow 

access for battery changing. 

Attach the box to the surface 

using the two screws and 

anchors included (if attaching 

to a plaster or masonry surface). use the wall clip (11) 

to secure the power cable (6) to a wall or other under-

counter surface if desired.

7. Insert four "D" batteries 

into the battery box (8). 

If the batteries are not 

properly installed or the 

cover is not properly 

positioned on the box, the 

system will not work. Position 

the cover (with batteries 

installed) on the battery box 

and tighten the two captive 

screws.

8. connect the two halves of 

the data cable (5) by visually 

lining up the white stripes on 

each half and gently pushing 

the cable connectors 

together until the stripes 

touch. Improperly assembled 

connectors can cause unit to 

not function as intended.

notE: After the batteries are installed in the 
battery box and the two halves of the data 

cable are connected, it will take approximately 
20 seconds before the touchfree counter 

Mounted system is ready to dispense soap.

rEFIll InstAllAtIOn (rEFIll sOlD sEPArAtEly)

9. Feed the dispense tube 

(A) on the refill bottle (9) 

up through the motor 

assembly/bottle support (7) 

and dispenser assembly, 

aligning the two indents in 

the bottle and the support. 

slide the bottle upward until 

it snaps into place.

notE: the refill is not properly installed until you 
hear the "snap" (as the green release latch on 
the motor assembly/bottle support (7) engages).

10. test the system by 

passing your hand under 

the spout of the dispenser 

assembly (1) (in front of the 

sensor window) at least 

three or four times, until 

foam soap appears. If the 

system does not dispense 

soap after passing your 

hand in front of the sensor 

several times, repeat 

several more times. If no 

sound is heard from motor 

assembly after placing 

hands in front of sensor, 

check to see that the 

data cable halves are 

firmly connected, that the batteries are "good", and 

that the battery box cover is properly positioned and 

fastened to the box. check for bent contact pins inside 

connector. If unit is multi-activating, check for bent 

contact pins inside connector.

instructions continuED

Actuation

zone

9

indents

A

1

7

5

8

6

11

8

5

5

1

1

7

6

Reviews: