PAGE 2 OF 3
0814 IH-2895
4. Align the indent inside the
tip of the motor assembly/
bottle support (7) with the
indent on the shank of the
dispenser assembly (1)
and firmly push the motor
assembly/bottle support up,
onto the shank.
notE: Hold the data cable (6) out of the way
as you push up on the motor assembly/bottle
support. continue pushing upward until the
vertical slots in the dispenser shank and the
motor assembly/bottle support line up.
5. secure the motor assembly/
bottle support (7) to the
dispenser assembly (1) shank
by pushing the retaining clip
(5) into place through the
vertical slots, until it goes all
the way through the motor
assembly.
notE: the clip may be inserted from either side.
6. remove the cover from the
battery box (8) by loosening
the two captive screws on the
battery box cover. Position the
box on a convenient (vertical
or horizontal) surface under
the counter top that will allow
access for battery changing.
Attach the box to the surface
using the two screws and
anchors included (if attaching
to a plaster or masonry surface). use the wall clip (11)
to secure the power cable (6) to a wall or other under-
counter surface if desired.
7. Insert four "D" batteries
into the battery box (8).
If the batteries are not
properly installed or the
cover is not properly
positioned on the box, the
system will not work. Position
the cover (with batteries
installed) on the battery box
and tighten the two captive
screws.
8. connect the two halves of
the data cable (5) by visually
lining up the white stripes on
each half and gently pushing
the cable connectors
together until the stripes
touch. Improperly assembled
connectors can cause unit to
not function as intended.
notE: After the batteries are installed in the
battery box and the two halves of the data
cable are connected, it will take approximately
20 seconds before the touchfree counter
Mounted system is ready to dispense soap.
rEFIll InstAllAtIOn (rEFIll sOlD sEPArAtEly)
9. Feed the dispense tube
(A) on the refill bottle (9)
up through the motor
assembly/bottle support (7)
and dispenser assembly,
aligning the two indents in
the bottle and the support.
slide the bottle upward until
it snaps into place.
notE: the refill is not properly installed until you
hear the "snap" (as the green release latch on
the motor assembly/bottle support (7) engages).
10. test the system by
passing your hand under
the spout of the dispenser
assembly (1) (in front of the
sensor window) at least
three or four times, until
foam soap appears. If the
system does not dispense
soap after passing your
hand in front of the sensor
several times, repeat
several more times. If no
sound is heard from motor
assembly after placing
hands in front of sensor,
check to see that the
data cable halves are
firmly connected, that the batteries are "good", and
that the battery box cover is properly positioned and
fastened to the box. check for bent contact pins inside
connector. If unit is multi-activating, check for bent
contact pins inside connector.
instructions continuED
Actuation
zone
9
indents
A
1
7
5
8
6
11
8
5
5
1
1
7
6