![U-Line Echelon CLRCO2175B40 Use And Care Manual Download Page 10](http://html1.mh-extra.com/html/u-line/echelon-clrco2175b40/echelon-clrco2175b40_use-and-care-manual_3422143010.webp)
8
CLR2160, CLRCO2175
Final Water/Drain Connection
1. Connect the water supply fitting by screwing the brass
garden hose fitting to the watervalve in the rear of
the unit.
2. Tighten this fitting with pliers.
Note:
Do not use Teflon tape or joint compound on this
fitting. The rubber washer provides an adequate seal.
Other materials could cause blockage of the valve.
Figure 12
3. Attach the copper water line to the back of the unit
using the supplied clamp and the back panel screw
(
Figure 12
, CLR2175 model shown). This will prevent
rotation of the line when moving the unit.
4. Plug in the unit and put unit into OFF mode by holding
the power key for 10 seconds. Not doing this will cause
the unit to fill with water for 3 minutes.
5. Turn on the water supply and ensure the connections
are free of leaks.
6. Begin to push the appliance into the desired cabinet
opening. The copper tubing should remain in 2 coils
behind the unit.
IMPORTANT
IMPORTANT
Normal operation creates some vibration. A water
supply line contacting cabinet wall may cause
excessive noise during operation or damage to the
line.
7. While pushing the unit into the opening, continuously
reroute the drain tube to avoid kinks. The most
common installation pulls the slack into an adjacent
cabinet or basement area.
8. If installing a gravity drain, ensure you provide proper
slope.
9. After unit is in its final position, finish routing drain
tube to the desired location. Common installations use
a floor drain, standpipe, garbage disposal, or Y-branch
tailpiece type drain connection (
Figures
8
,
9
and
10
).
10. Check to ensure unit is level both side to side and front
to back. See
Leveling
on
Page
16
.
IMPORTANT
IMPORTANT
For the gravity/floor drain or the standpipe be sure
to secure the drain line to these items to prevent it
from coming loose and causing water damage.
IMPORTANT
IMPORTANT
For disposer or Y-branch tailpiece connections press
the drain tube over the barbed end of the connector
and secure with a worm clamp. Make sure the
knockout inside the tailpiece has been removed for
both types of connections. Depending on the size of
the Y-branch or disposer fitting, an adapter may be
necessary to interface between the 5/8” hose and
connection.
11. Turn the unit to the on position by holding the power
key for 10 seconds.
12. Pour 1 gallon of water into the ice bin and check all
connections for leaks. Ensure the water is flowing from
the bin. If the water does not flow from the bin there
may be an issue with the drain connection, such as kinks
or improper slope. If your unit has a drain pump, an
indicator of P1 on the display will alert you of a slow or
clogged drain.
13. If any issues are found, retrace the drain connection,
correct the issue and retest with water.
Proced to
Electrical Specifications
.
ULIN_S_0166b1_A