U-Line Echelon BI 2015 Installation Manual Download Page 12

BI2015 — Ice Maker

www.U-LineService.com

12

02/2005

Checking Door Alignment

The unit’s door is aligned at the factory before shipment. 
However, its alignment could have been disturbed during 
shipment or during door panel installation.

IMPORTANT

Properly aligned, the door should be 1/8" below the top of 
the unit’s cabinet, NOT flush with the top (see 

Figure 26

).

1. Compare the top edge of the door to the top edge of 

the cabinet.

2. If the door edge is 1/8" below and parallel to the top of 

the cabinet, go on to 

6 Prepare Plumbing

. If it is not, 

note whether the side opposite the hinge needs to be 
moved UP or DOWN, and use the following procedure.

Note: 

If door is adjusted correctly, but panel is not square 

with the adjacent cabinets, slight adjustments can be 
made by drilling the holes in the vinyl coated steel panel 
slightly oversized. See 

Figure 21

 on 

Page

 

10

.

Adjusting Door Alignment

1. Remove top hinge screw 

pin (7/64" Allen wrench or 
Phillips screwdriver, 
depending on your unit’s 
construction, see 

Figure 

27

). Remove door by 

tilting forward and lifting 
off bottom hinge pin.

2. With door upside-down, 

loosen but do not remove 
the two screws on the 
door’s bottom hinge plate.

3. See 

Figure 28

. If the top far edge of the door needs to 

move UP, move the hinge plate toward the outside of 
the door and retighten screws. If the top far edge of the 
door needs to move DOWN, move the hinge plate 
toward the inside of the door and retighten screws.

4. Mount the door to recheck alignment and repeat Steps 

2 and 3 if further adjustment is necessary.

5. When top edge of door is parallel to top edge of 

cabinet, remove the door and ensure the two screws 
are secure.

6. Remove the door closers from the bottom hinge, clean 

thoroughly and lubricate the mating surfaces with 
petroleum jelly.

7. Reinstall the closers, lining 

up the bosses with holes in 
hinge and hinge plate (see 

Figure 29

).

8. Mount the door, install top 

hinge pivot pin and go on 
to 

6 Prepare Plumbing

.

5 Adjust Door

1/8"

Figure 26

Figure 27

Notch

Slotted

Mounting

Holes

Raise

Outside

Door Edge

Lower

Outside

Door Edge

Figure 28

Door

Closer

Inserts

Boss

Figure 29

Summary of Contents for Echelon BI 2015

Page 1: ...LineService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 BI2015 Ice Maker Installation...

Page 2: ...nection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for a...

Page 3: ...for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle across the top They come with a flush mounted door panel...

Page 4: ...require cleaning on a weekly basis Do not clean with steel wool pads Do not use cleaners that are not specifically intended for stainless steel this includes glass tile and counter cleaners If any su...

Page 5: ...are to the opposite side The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other side see Figure 4 To reverse the door 1...

Page 6: ...door into position in top hinge and install top hinge screw pin 10 Install plastic screw plugs removed in Step 2 in old hinge holes 3 each top and bottom Other Site Requirements Power Supply The unit...

Page 7: ...Black or White unit to harmonize with or accent the surrounding d cor a Custom 1 4 Insert or a Full Overlay If no custom door panel is used go on to 5 Adjust Door Custom 1 4 Door Panel Insert Door Pan...

Page 8: ...hinge pin and install upper hinge screw Go on to 5 Adjust Door Full Overlay Door Panel Door Panel Preparation A full overlay door panel completely covers the doorframe and handle to give a built in a...

Page 9: ...door hinge see Figure 16 Bottom View 5 16 diameter x 1 4 deep CAUTION It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardw...

Page 10: ...hrough both panels according to Figure 21 Remove tape adjoining the panels and enlarge the six holes in the overlay panel using a 0 201 7 drill 3 If a user supplied cabinet handle will be used attach...

Page 11: ...embly onto the bottom pivot post see Figure 25 Be sure that bosses on closers align with holes in hinge and hinge plate IMPORTANT Pivot posts must be cleaned Closers must also be clean and greased to...

Page 12: ...ver depending on your unit s construction see Figure 27 Remove door by tilting forward and lifting off bottom hinge pin 2 With door upside down loosen but do not remove the two screws on the door s bo...

Page 13: ...at the tubing is not pinched or damaged during installation U Line recommends the use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the...

Page 14: ...rd to connect power to the unit Go on to 8 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit is level If it is not level the ice mold will not fill evenly 1 Use a l...

Page 15: ...designed to align with the rest of the cabinet doors but the unit has crept forward Solution A Make sure that the electrical cord and water supply line are not obstructing the installation Initial St...

Page 16: ...ith water until the mold reaches the proper temperature Problem Q Water does not appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructe...

Page 17: ...es U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact th...

Reviews: