U-Line Echelon 2075DWRRSS Installation Manual Download Page 12

www.U-LineService.com

12

02/2005

2075DWRR — Drawer Model Refrigerator

Electrical Specifications

CAUTION

Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.

The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A power supply (normal household current). 
An individual, properly grounded branch circuit or circuit 
breaker is recommended. GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be 
sure to consult your local codes.

See 

Figure 23

 for recommended receptacle location. 

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Never remove the round grounding prong from 

the plug and never use a two-prong grounding 
adapter.

• Never use an extension cord to connect power to 

the unit.

Go on to

 7 Level the Unit

.

Leveling Information

Note: 

It is recommended that the unit is level. 

1. Use a level to check the 

levelness of the unit 
from front to back and 
from side to side. Level 
should be placed along 
top edge and side 
edge as shown (see 

Figure 24

).

2. If the unit is not level, 

adjust the feet on the 
corners of the unit 
as necessary (see 

Figure 25

).

3. Check the levelness after each adjustment and repeat 

the previous steps until the unit is level. Go on to 

8 Install the Unit

.

Installation Tip

If the room floor is higher than the floor in the cut-out 
opening, adjust the rear feet to achieve a total unit rear 
height of 1/8" less than the opening’s rear height. Shorten 
the unit height in the front by adjusting the front feet. 
This allows the unit to be gently tipped into the opening. 
Readjust the front feet to level the unit after it is correctly 
positioned in the opening.

6 Prepare Power Supply

1-1/2"

7"

23-11/16"

Figure 23

7 Level the Unit

Check

Level

Figure 24

Turn Foot to Adjust

Figure 25

Summary of Contents for Echelon 2075DWRRSS

Page 1: ...ce com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 2075DWRR Drawer Model Refrigerator Inst...

Page 2: ...ASE READ all instructions completely before attempting to install or operate the unit This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified e...

Page 3: ...drawers with top handles designed for the installation of full overlay drawer panels When full overlay panels will not be used replacement handles MUST be installed part number 11926 4 BLK Stainless S...

Page 4: ...s tile and counter cleaners If any surface discolors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain...

Page 5: ...op to allow for the installation of the Anti Tip Kit see Page 13 WARNING The Anti Tip Kit must be installed on this unit before it is used Never use the drawers as steps or as a shelf to support more...

Page 6: ...itional clearance in front of the open drawer for convenience Other Site Requirements Power Supply The unit requires a grounded and polarized 115 VAC 60 Hz 15A circuit normal household current See Ele...

Page 7: ...installed facing an appliance or structure see Page 5 Cut the panel inserts to the following dimensions Custom 1 4 Dimensions Width 23 1 32 Height 12 15 16 The door panels must not have a total weight...

Page 8: ...emove and save the two screws located at the ends of the handle see Figure 8 Remove the handle 3 Remove existing panel and cardboard spacer Discard the spacer Attaching the Full Overlay Panel 1 If use...

Page 9: ...moving Existing Drawer Fronts 3 Starting at the corners and working toward the center push the drawer gasket back into place Go on to 5 Adjust Drawers Checking Drawer Alignment The unit s drawers are...

Page 10: ...caused by one of the slides being mounted too far forward on the unit s liner Minor Adjustment Note The mounting holes on the slide are slightly larger than the screws diameter 1 Loosen the slide s mo...

Page 11: ...mounting screws 2 Push the slide upward or downward to match the position of the other slide 3 Retighten the screws See Figure 21 4 Repeat the procedure with the other slide if necessary Severe Adjust...

Page 12: ...g grounding adapter Never use an extension cord to connect power to the unit Go on to 7 Level the Unit Leveling Information Note It is recommended that the unit is level 1 Use a level to check the lev...

Page 13: ...ting surface to support the weight of the drawers and the items that will be inside the drawers Never use the drawers as steps or as a shelf to support more than the drawers content Serious personal i...

Page 14: ...ON position Temperature Controller The temperature controller Figure 28 is located in the top drawer It consists of an LED display two LED status indicator lights and three touchpad buttons The LED d...

Page 15: ...on Removing the upper drawer s storage bin Removing the lower drawer s crisper Adjusting the drawer s organizer left to right or front to back Start Up Troubleshooting Problem Q Unit does not appear t...

Reviews: