background image

QUICK START GUIDE

5

u-line.com

9. Install retaining clip.

Door Swing

CRESCENT ICE MAKERS, OUTDOOR SERIES AND 
ADA15IM

Units have a zero clearance for the door to open 90°, 
when installed adjacent to cabinets. 

Stainless Steel and black and white models require 2-1/8" 
(54 mm) door clearance to accommodate the handle if 
installed next to a wall. 

Integrated models require 1/4" (6 mm) clearance if 
installed next to a wall. Allow for additional space for any 
knobs or pulls installed on the integrated panel/frame.

BI95/BI98

All units have a zero clearance for the door to open 90°. 
U-Line recommends a minimum door clearance of 1/4" 
(6 mm) to accommodate the handle if the unit is installed 
next to a wall. 

MARINE SERIES

All units have a zero clearance for the door to open 90°. 
U-Line recommends a minimum door clearance of 3/4" 
(19 mm) to accommodate the handle if the unit is 
installed next to a wall or similar type of structure. 

Wall

Wall

90°

Door Swing

90°

Door Swing

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

1/4" Min. (6 mm)

90°

Door Swing

3/4" (19 mm) Min. 

Wall

90°

Door Swing

Summary of Contents for Combo U-CO29FB-00A

Page 1: ...QUICK START GUIDE Combo Models 115 V 60 Hz ...

Page 2: ...p to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product pleas...

Page 3: ...tents 1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 5 Door Swing 6 General Installation 7 Integrated Panel Installation 10 Control Operation 11 First Use 11 Ice 12 Sabbath Mode 12 Warranty ...

Page 4: ...com to view detailed User Guides for all U Line products Combo Models U CO29FB 00A U CO29FW 00A U CO1224FS 00B U CO1224FINT 00B U CO1224FB 40B U CO1224FW 00B Marine Series ULN CO29B 03A ULN CO29B 20A ULN CO29W 03A ULN CO29W 20A Visit http www u line com product literature userguides or scan this QR code to view all user guides online ...

Page 5: ...to follow this safety statement may result in minor or moderate personal injury property or equipment damage Environmental Requirements This model is intended for indoor interior applications only and is not to be used in installations that are open exposed to natural elements This unit is designed to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s abilit...

Page 6: ...or your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4 6 35 mm compression fitting U Line recommends using accessory water hook up kit part WATERHOOKUP The kit includes a 10 3 m braided flexible water supply line and a brass hose fitting When using a 1 4 6 35 mm O D soft copper supply...

Page 7: ...ge and or harm flooding or void the product warranty Use new hose set Do not reuse old hose set CAUTION Turn off water supply and disconnect electrical supply to unit prior to installation Use caution when handling back panel The edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the back panel 3 Locate water valve inl...

Page 8: ...r additional space for any knobs or pulls installed on the integrated panel frame BI95 BI98 All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 1 4 6 mm to accommodate the handle if the unit is installed next to a wall MARINE SERIES All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 3 4 19 mm to ac...

Page 9: ...wipe out the inside of the unit with a clean water dampened cloth CRESCENT ICE MAKERS OUTDOOR SERIES AND ADA15IM LEVELING INFORMATION 1 Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown 2 If the unit is not level adjust the legs on the corners of the unit as necessary 3 Confirm the unit is level after each adjustment and repeat the previous steps...

Page 10: ...nge screw pin with Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove two outside screws holding door handle Slightly separate door handle from door 4 Pull handle up and off 5 Slide custom door panel insert into ...

Page 11: ...ding cabinetry the panel may not sit flush with the top of the door drawer 9 Secure integrated panel to door drawer using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door drawer If using tape be certain the tape will not damage panel finish upon removal 10 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep...

Page 12: ...on the gasket channel and sit flush against the bottom of the channel 14 Remove clamps from door drawer If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion Integrated Panel Integrated Panel ...

Page 13: ...n Light Power Not Used LED CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and beverage centers only Adjust refrigerator set point Press and release When the F or C in the display is flashing press to adjust the set point temperature View temp...

Page 14: ...it will preserve temperature for ice storage NOTICE If not intending to use the ice maker turn the water supply valve off It is also important to raise the bin arm of the ice maker see above Failure to raise the bin arm may result in damage to the water valve Certain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice ...

Page 15: ...ch U Line product to be free from defects in materials and workmanship for a period of five years from the date of installation 2 During the initial one year warranty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including ...

Page 16: ...es of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from a hose or similar device into and around the unit 7 If a product defect is discovered during the applicable warranty period you must promptly notify U Line at 1 800 779 2547 or the dealer from whom ...

Reviews: