background image

08/2006

13

www.U-LineService.com

CLRCO2175 Combo®— Clear Ice Maker/Refrigerator

CAUTION

Plumbing installation must observe all state and local 
codes. All water and drain connections MUST BE made by 
a licensed/qualified plumbing contractor. Failure to follow 
recommendations and instructions may result in damage 
and/or harm.

Drain Connection

IMPORTANT

Drain can NOT be located directly below unit. Unit has a 
solid base that will not allow unit to drain below itself.

The CLRCO2175 can be installed using a Gravity Drain, a 
Factory-Installed Drain Pump (U-Line P60) or a Locally-
Installed (U-Line P60) Drain Pump. Drain lines must have a 
5/8-inch inside diameter. The floor drain must be large 
enough to accommodate drainage from all attached 
drains.

Follow these guidelines when installing drain lines to 
prevent water from flowing back into the ice maker 
storage bin and/or potentially flowing onto the floor, 
causing water damage:

Gravity Drain

A Gravity Drain may be used if:

• Drain line has at least a 1-inch drop per 48 inches of 

run (1/4 inch per foot).

• Drain line does not create traps or created traps are 

vented (see 

Figure 31

).

See 

Figure 32

 for a typical Gravity Drain installation.

If using a Gravity Drain:

1. Attach the 5/8-inch ID drain connection on the back of 

the unit to a 5/8-inch OD rigid tube, using a worm 
clamp.

2. Attach the other end of the rigid tube to your 5/8-inch 

ID drain line with a worm clamp.

3. Insulate the drain line, if necessary to prevent 

condensation. Go on to 

Water Supply Connection

.

Factory-Installed Drain Pump

If your drain line will run up to a stand pipe, disposal 
assembly or spigot assembly or does not otherwise meet 
the requirements for a Gravity Drain, you may have 
ordered the CLRCO2175 with a U-Line P60 Drain Pump. 
See 

Figures

 

33

34

 and 

35

 for typical installations 

requiring a Drain Pump. If you need to install a P60 Drain 
Pump into your unit, see 

Locally-Installed Drain Pump

 on 

Page

 

15

.

6 Prepare Plumbing

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

Figure 31

Waste

Waste

Cold

Water

Shut-Off

Valve

Hot

Water

Figure 32

Gravity Drain

Cold

Water

Hot

Water

Waste

Waste

Shut-Off

Valve

Figure 33

Stand Pipe

Summary of Contents for CLRCO2175

Page 1: ...m Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 08 2006 CLRCO2175 Combo Clear Ice Maker Refrigerator...

Page 2: ...property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a drain Improper connection...

Page 3: ...ave a reversible door with a slightly contoured handle across the top They come with a flush mounted door panel that when removed will accept a custom 1 4 inch thick door panel or a 3 4 inch thick ful...

Page 4: ...steel this includes glass tile and counter cleaners If any surface discolors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in th...

Page 5: ...ly reversed by moving the hinge hardware to the opposite side The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other sid...

Page 6: ...er supply line and a shut off valve For more information see Page 15 Drain The unit s generous 7 inch drain connection height extends the distance the unit can be located from a gravity drain For more...

Page 7: ...ze with or accent the surrounding d cor a Custom 1 4 Insert or a Full Overlay If no custom door panel is used go on to 5 Adjust Door Custom 1 4 Door Panel Insert Door Panel Preparation A custom door p...

Page 8: ...r on bottom hinge pin and install upper hinge screw Full Overlay Door Panel Door Panel Preparation A full overlay door panel completely covers the doorframe and handle to give a built in appearance Se...

Page 9: ...nge screw pin Phillips screwdriver Remove the door by tilting forward and lifting off the bottom hinge pin 3 Pull door gasket out of the groove top edge of door only Start in the middle and pull outwa...

Page 10: ...verlay Handle and secure with the two screws removed in Step 4 under Removing Existing Door 3 Attach Overlay cap to door opposite side of where hinges will be see Figure 23 Removed Door Panel Top of W...

Page 11: ...and hinge plate IMPORTANT Pivot posts must be cleaned Closers must also be clean and greased to ensure proper operation 5 Place the modified door onto the pivot post 6 Position door and install the pi...

Page 12: ...Phillips screwdriver see Figure 28 Remove door by tilting forward and lifting off bottom hinge pin 2 With door upside down loosen but do not remove the two screws on the door s bottom hinge plate 3 Se...

Page 13: ...a 1 inch drop per 48 inches of run 1 4 inch per foot Drain line does not create traps or created traps are vented see Figure 31 See Figure 32 for a typical Gravity Drain installation If using a Gravit...

Page 14: ...ully push the power cord grommet through the hole in the back panel see Figure 36 3 Remove 12 screws and back panel WARNING Back panel serves as a guard DO NOT put your hands inside the ice maker cabi...

Page 15: ...does not allow water leakage in the case of a power outage restricted drain or pump failure It must have a check valve in the discharge line to prevent waste water return to the pump It must have an...

Page 16: ...ualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended...

Page 17: ...should be placed along top edge and side edge as shown see Figure 43 2 If the ice maker is not level adjust the feet on the corners of the unit as necessary see Figure 44 3 Check the levelness after...

Page 18: ...the right wall pull the shelf out 4 Choose new location and insert over ribs tilting right hand edge up Push in then lower shelf onto ribs Door Shelves 1 First pull shelf up at a 45 angle then straigh...

Page 19: ...nds 3 minutes The compressor begins to operate 4 Watch the water flow over the evaporator assembly ice cube tray to familiarize yourself with the operation Upon initial start up water flow over the ev...

Page 20: ...the drain line is not obstructed unit will shut down due to the safety design of the pump if water cannot drain Problem Q Water does not appear to be flowing into unit Solution A Check that the water...

Page 21: ...itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises call the U Line Customer Care Center...

Reviews: