Problem
Possible Cause
Remedy
The unit is not
Light staying on.
Call for service.
cold enough.
Dirty condenser coils.
Clean condenser. Refer to
CONDENSER CLEANING
.
Airflow to front grille
Airflow must not be
blocked.
obstructed to front grille.
Refer to
INSTALLATION
.
Temperature not set
Use the temperature
cold enough.
controller to set
temperature colder.
Allow 24 hours for
temperature to stabilize.
Door is not closing
Make sure no obstructions
completely.
are blocking the door and
unit is level. Refer to
LEVELING THE UNIT
.
Door adjustment required.
Refer to
DOOR
ADJUSTMENT
.
Cycle Selector Switch in
Turn Cycle Selector Switch
OFF position.
to ON.
Temperature
Drain pump blocked.
Check installation and
controller LED
drain line for kinks.
flashing.
Unit malfunction.
Call for service.
Noise during
Certain sounds
Soft sounds from the fan
operation.
are normal.
and water/dropping
sounds from the ice
maker will be heard.
Fresh food section
Temperature control
Use the temperature
on Combo units
set too cold.
controller to set
too cold.
temperature warmer
.
The unit does
Low air temperature
Surrounding air
not operate.
around unit.
temperature must be at
least 50°F (10°C).
Unit runs but no
No water being
Check to see that water
ice is produced.
supplied to the unit.
is connected and turned
on to the unit.
40