U-Line Corporation | Limited Warranty

1. U-Line Corporation (“U-Line”) warrants each U-Line 

product to be free from defects in materials and 
workmanship for a period of one year (two years on 
Modular 3000 Series) from the date of installation. U-
Line further warrants the sealed system (consisting of 
the compressor, condenser, evaporator, hot gas 
bypass valve, dryer, and connecting tube) in each U-
Line product to be free from defects in materials and 
workmanship for a period of five years from the date of 
installation.

2. During the initial one year warranty period (two years 

on Modular 3000 Series) for all U-Line products U-Line 
shall: (1) repair any product or replace any part of a 
product; and (2) for all Marine, RV and Domestic U-
Line products sold and serviced in the United States 
(including Alaska and Hawaii) and Canada, U-Line shall 
be responsible for the labor costs performed by a U-
Line authorized service company, incurred in 
connection with the replacement of any defective part. 
During years two through five of the warranty period 
for the sealed system, U-Line shall: (1) at U-Line’s 
option repair or replace any part of the sealed system; 
and (2) for all Marine, RV and Domestic U-Line 
products sold and serviced in the United States 
(including Alaska and Hawaii) and Canada, U-Line shall 
be responsible for the labor costs incurred in 
connection with the replacement of any defective part 
of the sealed system. All other charges, including 
transportation charges for replacements under this 
warranty and labor costs not specifically covered by 
this warranty, shall be the responsibility of the 
purchaser. This warranty extends only to the original 
purchaser of the U-Line product. The Product 
Registration Card included with the product should be 
promptly completed by you and mailed back to U-Line 
or you can register on-line at 

www.u-line.com

.  

3. The warranty listed above does not apply to floor 

display models. The warranty for these models shall be 
one year from the date of installation. This one-year 
warranty does not apply to cosmetic damages; proof of 
purchase may be required. 

4. The following conditions are excluded from this limited 

warranty: use of cleaners other than the recommended 
stainless steel cleaners and U-Line Clear Ice Maker 
cleaner; installation charges; damages caused by 
disasters or acts of God, such as fire, floods, wind and 
lightning; damages incurred or resulting from shipping, 
improper installation, unauthorized modification, or 
misuse/abuse of the product; customer education 
calls; food loss and spoilage; door and water level 
adjustments (except during the first 30 days from the 
date of installation); defrosting the product; adjusting 
the controls; door reversal; and cleaning the 
condenser.

5. U-Line products are designed to operate in ambient 

temperatures between 50°F and 100°F unless 
otherwise noted in the product manual. Exposure to 
temperatures outside this range may cause 
degradation of performance and issues such as lower 
ice production or spoiled contents are not covered 
under the terms of this warranty as a result of that 
exposure. U-Line product may not be subjected to 
temperatures below 40°F without following the 
winterization and vacation shutdown procedures in 
your product manual.

6. U-Line’s Outdoor Limited Warranty, set forth in this 

Paragraph 6, shall apply to U-Line models deemed 
suitable for outdoor use by Underwriters Laboratory 
(“UL”) as noted in the U-Line Product Catalog, U-Line’s 
website and/or on the serial tag located inside the 
product. Outdoor product may come into contact with 
rain by virtue of outdoor use. Exposure to other 
sources of water shall also cause this warranty to be 
void, including flooding of the area in proximity of the 
unit greater than 1/8" deep in water, hurricanes, 
splashing of pool water, or directing a spray from a 
hose or similar device into and around the unit. 

7. If a product defect is discovered during the applicable 

warranty period, you must promptly notify U-Line at 1-
800-779-2547 or the dealer from whom you purchased 
the product. In no event shall such notification be 
received later than 30 days after the expiration of the 
applicable warranty period. U-Line may require that 

Summary of Contents for ADA24RS13B

Page 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE ADA Series ADA24R 24 Solid Door Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...l Requirements Electrical Cutout Dimensions Product Dimensions Side by Side Installation Anti Tip Bracket General Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Operating Ins...

Page 3: ...or additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u li...

Page 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Page 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Page 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Page 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Page 8: ...allation When built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in t...

Page 9: ...ER GUIDE Product Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 23 1 4 591 mm 32 to 33 813 mm 838 mm 24 610 mm Not Including Hand...

Page 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...

Page 11: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...

Page 12: ...adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be ge...

Page 13: ...the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to...

Page 14: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...

Page 15: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...

Page 16: ...e door TO ALIGN AND ADJUST THE DOOR Remove grille Remove the grille see GRILLE PLINTH INSTALLATION section of this guide 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with c...

Page 17: ...epare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws hol...

Page 18: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the f...

Page 19: ...ROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine...

Page 20: ...tain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will...

Page 21: ...perform as expected When loading your unit leave space between the internal fans or vents and product loaded Anything blocking the required airflow circulation will result in uneven temperature distr...

Page 22: ...he hump on the right hand side 3 Tilt up right hand edge of shelf 2 4 Remove shelf from unit by pulling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf a...

Page 23: ...ass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finis...

Page 24: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...

Page 25: ...ental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins...

Page 26: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...

Page 27: ...s listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air...

Page 28: ...r openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be ena...

Page 29: ...ese models shall be one year from the date of installation This one year warranty does not apply to cosmetic damages proof of purchase may be required 4 The following conditions are excluded from this...

Page 30: ...exclusive remedy under this warranty are set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or in...

Reviews: