To measure the start winding resistance, measure across
the C and S pins.
To measure the run winding resistance, measure across
the C and R pins.
Also check S to R and you should get the sum of the run
and start windings.
To ensure the windings are not shorted, check the S and R
to ground.
* All resistance readings are ±10%
EM150HER
Refrigerant
R134a
Voltage
115 VAC
Frequency
60 Hz
Run Cap
n/a
Start Winding
12.1 Ohm at 77°F
Run Winding
3.9 Ohm at 77°F
LRA
18.0 A
FLA
2.0 A
Starting Device
213514105
Overload
4TM757KFBYY-53