U-Line 5 Series Quick Start Manual Download Page 8

QUICK START GUIDE

u-line.com

Anti-Tip Bracket

Use one of the methods below to secure the unit

CABINET/COUNTER ANTI-TIP INSTALLATION

     (For built-in applications)

1.  Slide unit out so screws on front of unit are easily         

accessible.

2.  Remove the two screws from the front of the unit.

   

3.  Bend bracket along one of the perforations to allow 

attachment to the desired adjoining surface.

4.  Gently push unit into position. Be careful not to 

entangle the electrical cord or water line, if applicable.

5.  Check to be sure the unit is level from front to back 

and side to side. Make any necessary adjustments. 
The unit’s top surface should be approximately 

1⁄8

”     

(3 mm) below the countertop.

6.  Secure bracket to adjoining surface.

FLOOR MOUNTED ANTI-TIP INSTALLATION

     (For free-standing applications)

1.  Locate two anti-tip brackets included with the kit.

2.  Place the unit into the area where it will be installed. 

Check the door, sides, and top for a proper fit. Also 

test to make sure the door opens and closes freely.

3. 

Remove grille and place a mark on the floor at the 
front of the unit. Also place a mark on the floor in the 

center of the unit.

4.  Remove the unit. Using a square, extend center line 

“B” (see chart below). This line serves as the back 
edge for the anti-tip brackets. From the center line, 
measure “A” to the left and right. This line is the outer 
edge of each bracket.

CL

Back wall

Back of unit

Front of unit

Surrounding

area (Top view)

A

A

B

515

518

524

A

5⁄8”

9”

11 

15⁄16

B

22”

22”

22”

5. 

Place the anti-tip brackets on the floor against the line 

drawn for the outer edge. Mark spots for the screw 
holes.

C

L

Surrounding

area (Top view)

Drill holes and

mount anti-tip

brackets to floor

Back wall

Front

of 

unit

Back

of 

unit

A

A

B

6.  Use a 1/8” drill to make two starter holes and fasten 

the anti-tip brackets to the floor using the screws 

provided.

7.  Place the unit back into position, making sure the 

feet engage the anti-tip brackets properly. Check 

the alignment of the lines made on the floor in step 

3 with the position of the front feet to ensure proper 
positioning.

8

Summary of Contents for 5 Series

Page 1: ...QUICK START GUIDE 5 CLASS 30633_D...

Page 2: ...ucts are available worldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance D...

Page 3: ...product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 5 Door Stop 6 Door Adjustments 6 General Installation 7 Anti...

Page 4: ...failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for...

Page 5: ...s of property and or life and will void the warranty Never use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state an...

Page 6: ...door is open approximately 6 150 mm about 25 Door Adjustments DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or not sealing properly If the door is not sealed the unit may...

Page 7: ...p edge and side edge as shown 2 If the unit is not level adjust the legs on the corners of the unit as necessary 3 Confirm the unit is level after each adjustment and repeat the previous steps as need...

Page 8: ...proper fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4 Rem...

Page 9: ...ll bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in o...

Page 10: ...on Press and release to leave interior light on for 12 hours press again to deactivate After 12 hours factory default is restored light will turn on when door is open Hide Display Hold and press Displ...

Page 11: ...champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capacities U Line uses typical 12 oz cans 12 oz bottles 750 mL white wine and red wine bo...

Page 12: ...avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the rack have a thin coating which is used to block moisture and provide lubrication Use care when handling Wine...

Page 13: ...ottles so the wine remains in contact with the cork which ensures the cork does not become dry Racks are designed to accommodate typical 750ml wine bottles as follows UHWC515 15 Wine Captain Models UH...

Page 14: ...ure and provide lubrication Use care when handling Slide and Secure Storage Bin Installation 1 Insert empty storage bin frame into unit with one side tilted slightly downward until back pin is between...

Page 15: ...in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean...

Page 16: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Reviews: