NOTE: Air temperature does not reflect product
temperatures.
The graph below shows a unit’s cooling cycle over time
with various differentials.
Set Points
The Set points menu contains options to modify both the
Zone and Evap set points. Changes to the zone set point
will be reflected on the main screen. Changes to the evap
set point alter the temperature the evaporator needs to
meet during a defrost cycle.
To access Set Points
1. Press to select “Set Points”.
2. Press .
3. Press and to scroll through available set points.
To change set point
4. Press , the selected set point will begin to flash.
5. Press or to modify the value.
6. Press to confirm setting.
To exit the Set Points menu, press to select “Return to
Menu” and press to confirm.
Factory Default
Factory Default will restore all settings to their factory
default.
To access Factory Default
1. Press to select “Factory Default”.
2. Press .
To restore settings to their factory default.
3. Press to select “Restore?” and press
4. “Restore?” will change to “Restoring...” while settings
are restored. When restoration is complete,
“Restoring...” will return to “Restore?”.
To exit Factory Default, press to select “Return to
Menu” and press to confirm.
Differential
Cycle Start °F (°C) Cycle End °F (°C)
0
46 (8)
44 (7)
1
47 (8)
43 (6)
2
48 (9)
42 (6)
3
49 (9)
41 (5)
4
50 (10)
40 (4)
5
51 (11)
39 (4)
p'LɞHUHQWLDO
p'LɞHUHQWLDO
p'LɞHUHQWLDO
Up
Select
Down
RETURN TO MENU
SET POINTS
ZONE = 38°F
EVAP = 42°F
Can be displayed in Celsius
Up
Select
Down
RETURN TO MENU
FACTORY DEFAULT
RESTORE?