U-Line 29R Installation Manual Download Page 4

www.U-LineService.com

4

02/2005

29R Refrigerator

Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit 
does not require additional air space for top, sides or rear. 
However, the front grille must NOT be obstructed and 
clearance is required for electrical connections in the rear.

Note: 

Unit can NOT be installed behind a closed cabinet 

door.

Cut-Out Dimensions

Follow the cut-out drawing in 

Figure 1

. The 21-1/16" 

width allows 1/4" for ease in installation and removal of 
the unit. 24" is the counter depth in most installations. 
The unit is 23" deep including the door and handle (see 

Figure 2

). 

Note: 

It is recommended that the unit is level. 

Product Dimensions

Door Swing/Clearances Information

Units have a zero clearance for the door to open 
90° (see 

Figure 3

). U-Line recommends a minimum door 

clearance of 1/4" to accommodate the handle if the unit is 
right-hand hinged and installed next to a wall or similar 
type of structure.

3 Prepare Site

23"

Minimum

21-1/16"

See Electrical

Specifications

for Power Supply

Typical

Counter

Height

34-1/4"

to

35-1/8"

Cut-Out

Height

28-5/8"

to

28-7/8"

Filler Panel (Not Provided by U-Line) –

May Be Added Above or Below Unit

to Enclose for a Built-In Look 

Figure 1

23"

Including

Handle

28-1/2"

20-13/16"

Figure 2

1/4" Min.

Wall

90°

Door Swing

20-7/16"

22-3/8"

Figure 3

Summary of Contents for 29R

Page 1: ...LineService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 29R Refrigerator Installation...

Page 2: ...re attempting to install or operate the unit This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician in accordance with applicable...

Page 3: ...nd a Product Registration Card Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide...

Page 4: ...stallations The unit is 23 deep including the door and handle see Figure 2 Note It is recommended that the unit is level Product Dimensions Door Swing Clearances Information Units have a zero clearanc...

Page 5: ...talled Align hinge outer edge with cabinet before tightening screws 5 Relocate plastic spacer bushing on bottom of door to opposite side and place door on bottom hinge pin See Figure 8 Clean out bushi...

Page 6: ...with or accent the surrounding decor If this treatment is not included in this installation go on to 5 Adjust Door Custom 1 4 Thick Door Panel Insert Door Panel Preparation A custom door panel can be...

Page 7: ...or Alignment The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment or during door panel installation IMPORTANT Properly aligned the...

Page 8: ...t recommended for your unit because a GFCI could be prone to nuisance tripping However be sure to consult your local codes See Figure 16 for recommended receptacle location WARNING SHOCK HAZARD Electr...

Page 9: ...the grille itself It is located toward the top of the middle recessed section of the grille 4 Place the two hook hinges located on the rear bottom side of the grille onto the front lip of the unit ba...

Page 10: ...this time For information about Adjusting the Temperature Control see the User Manual Start Up Troubleshooting Problem Q Unit does not appear to turn on when plugged in Solution A Make sure outlet ha...

Reviews: