USER GUIDE
Service Mode 2
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
ERRORS
*All errors are logged in memory.
*Only door error is displayed on the display and has an
audible signal.
*For 68118 models, pump error is displayed via alert light
with no audible alert.
E1:
Thermistor 1 open.
E2:
Thermistor 2 open.
E3:
Thermistor 3 open.
E4:
Thermistor 4 open.
E5:
Thermistor 1 shorted.
E6:
Thermistor 2 shorted.
E7:
Thermistor 3 shorted.
E8:
Thermistor 4 shorted.
E9:
Door open error.
PI:
Pump Circuit open
Programming the unit to correct model number
1. Unplug unit and install new board
2. Push and hold the hidden icon
3. Plug the unit in
4. Release the hidden icon
5. Use the UP/DOWN arrows to scroll to correct model
number from chart
6. Push and release the light icon
7. Unit flashes OFF/ON then locks in model
1000
Model
#
2000
(120V)
Model
#
2000
(230V)
Model
#
1215R 07
2218R
05
2245R
55
1215WC
12 2218RG
04 2245RDC
54
1224BEV 13
2218WC 06
224WC
57
1224DWR 08 2224BEV
00 2260DC 50
1224R 14
2224FZR
11
2260FZR 57
1224RF
09
2224R
02
2260R
52
1224RSOD 10 2260R
01 2260RDC 51
1224WC 15
2224RG
03
2260WC
53
CLR 1215
18
ADA24R
17
CO 1224F
19