 1.  GENERAL

   

 1.01

 Dimensions inverters have been designed

and manufactured for many user applications and
long life.  They utilize patented construction meth-
ods and high technology electronic parts and
circuitry.
   

 1.02

 CAUTION:

 

 Inverters produce hazardous

voltages, to avoid  risk of harm or fire the unit must
be properly installed. There are no user serviceable
parts inside, do not remove the cover.
CAUTION:

 

 The inverter should not be mounted in

a location that may be exposed to rain or spray.
CAUTION:

 

 The inverter should not be installed in

a zero clearance enclosure.
CAUTION:  Damage to the inverter will occur if
correct polarity is not observed when installing the
DC input cables.
CAUTION:  Damage to the inverter will occur if an
external AC power source is applied to the inverter’s
AC output or its hardwire output.
CAUTION:  The inverter contains a circuit breaker
and capacitor that may produce a spark. Do not
mount in a confined battery or  gas compartment.
CAUTION:   Working in the vicinity of lead-acid
batteries is dangerous. Batteries generate explo-

sive gases during operation.  There is a risk of acid
exposure. There is also a risk of high  current
discharge from shorting the battery that can cause
fire and explosion.
CAUTION:  Be sure the inverter's circuit breaker
or fuse are turned off during installation.

    2.  DESCRIPTION

     

 2.01

    The inverter converts 12 VDC to 120

VAC, 60 HZ, having a pure sine wave form.

  

 

    2.02 

The inverter has a controlled frequency

at 60 HZ + 0.05%.
  

   2.03     

The inverter has internal protection

against output short circuit, output overload and
high temperature conditions.  Also, there is a
thermally controlled cooling fan.
    

  2.04 

The inverter is designed to operate any

120 VAC,  60 HZ single phase appliance, equipment
or tool within its power ratings.

                     Inverter Rating

    Inverter       Input               Output___
    Model      (VDC)   (ADC)   (VAC) (Watts)

   

 12/800N   12.6   Up to 80    120     800

    12/1200N  12.6  Up to 120  120    1200

    3.  INSTALLATION

  

   3.01 

   The following instructions should be

thoroughly read and understood before installa-
tion.
    

  3.02

   CAUTION: Inverters produce hazard-

ous voltages, to avoid risk of harm or fire the unit
must be properly installed.
CAUTION:   Damage to the inverter will occur if
correct polarity is not observed when installing

 

the

DC input cables.
 

CAUTION:  Damage to the inverter will occur if an

external AC power source is applied to the inverter’s
AC outlet or its hardwire output.
CAUTION:  Be sure  the inverter's circuit breaker
or fuse are turned “OFF”during installation.

NOTE: 

 All wiring must follow the National Electric

Code, Provincial or other codes in effect at the time