ZED-F9H - Integration manual
For more information about the default configuration, see the applicable interface description [
3.1.3 Default interface settings
Interface
Settings
UART1 output
38400 baud, 8 bits, no parity bit, 1 stop bit.
NMEA protocol with
GGA, GLL, GSA, GSV, RMC, VTG, TXT
messages are output by default.
UBX protocol is enabled by default but no output messages are enabled by default.
RTCM 3.3 protocol output is not supported.
UART1 input
38400 baud, 8 bits, no parity bit, 1 stop bit.
UBX, NMEA and RTCM 3.3 input protocols are enabled by default.
UART2 output
38400 baud, 8 bits, no parity bit, 1 stop bit.
UBX protocol cannot be enabled.
RTCM 3.3 protocol output is not supported.
NMEA protocol is disabled by default.
UART2 input
38400 baud, 8 bits, no parity bit, 1 stop bit.
UBX protocol cannot be enabled and will not receive UBX input messages.
RTCM 3.3 protocol is enabled by default.
NMEA protocol is disabled by default.
USB
Default messages activated as in UART1. Input/output protocols available as in UART1.
I2C
Fully compatible with the I2C
industry standard, available for communication with an external
host CPU or u-blox cellular modules, operated in slave mode only. Default messages activated as
in UART1. Input/output protocols available as in UART1. Maximum bit rate 400 kb/s.
SPI
Allow communication to a host CPU, operated in slave mode only. Default messages activated as
in UART1. Input/output protocols available as in UART1. SPI is not available unless D_SEL pin is
set to low (see the
Table 1: Default interface settings
UART2 can function as the main correction interface; RTCM 3.3 (from a ZED-F9P moving base)
is the default input protocol. UART2 can also optionally be configured for NMEA input or output
protocol.
Refer to the applicable interface description [
] for information about further settings.
By default the ZED-F9H outputs NMEA messages that include satellite data for all GNSS
bands being received. This results in a high NMEA load output for each navigation period.
Make sure the UART baud rate used is sufficient for the selected navigation rate and the
number of GNSS signals being received.
3.1.4 Basic receiver configuration
This section summarizes the basic receiver configuration most commonly used.
3.1.4.1 Communication interface configuration
Several configuration groups allow operation mode configuration of the various communication
interfaces. These include parameters for the data framing, transfer rate and enabled input/output
protocols. See
section for details. The configuration groups available for
each interface are:
Interface
Configuration groups
UART1
CFG-UART1-*, CFG-UART1INPROT-*, CFG-UART1OUTPROT-*
2
I2C is a registered trademark of Philips/NXP
UBX-19030120 - R04
3 Receiver functionality
Page 12 of 101
C1-Public