XPLR-IOT-1 - User guide
UBX-21035674 - R03
Platform description
Page 30 of 42
C1-Public
3.8
Jumpers
The PCBA includes several jumpers to select features and for current measurement. Normally open
jumpers can be closed by creating a solder bridge across the terminals.
Normally open
solder jumper
Description
Remarks
NO1
SARA-R5 power
Close to power SARA-R5 when SW1 is on
NO2
NINA-W15 power
Close to power NINA-W15 when SW1 is on
NO3
SARA-R5 USB
Close to enable diagnostic USB interface
NO4
Magnetometer interrupt
Close to enable interrupt (also open NC7)
NO5
Gyroscope interrupt
Close to enable interrupt (also open NC7)
NO6
GNSS receive path
Close to enable LNA/SAW filter path
Table 17: Normally open solder jumpers
Normally, closed jumpers can be opened by cutting the trace between the two pads. They may be
closed again by creating a solder bridge across the terminals.
Normally closed
solder jumper
Description
Remarks
NC1
NINA-W15 reset
Open to isolate from system reset
NC2
SARA-R5 power indicator
Open to disable LED D7
NC3
NINA-W15 power indicator
Open to disable LED D8
NC4
SARA-R5 reset
Open to isolate from system reset
NC5
NINA-W15 current measurement
Open to allow use of J2
NC6
SARA-R510 current measurement
Open to allow use of J3
NC7
Ambient light sensor interrupt
Open to disable interrupt
NC8
USB-UART reset
Open to isolate from system reset
NC9
NORA-B1 current measurement
Open to allow use of J4
NC10
MAX-M10 reset
Open to isolate from system reset
NC11
USB hub reset
Open to isolate from system reset
NC12
NORA-B1 reset
Open to isolate from system reset
NC13
MAX-M10 current measurement
Open to allow use of J6
NC14
MAX-M10 power indicator
Open to disable LED D21
NC15
System current measurement
Open to enable use of J10
Table 18: Normally closed solder jumpers
The current of various system components is measured through the jumpers noted in
Jumper
Description
J2
NINA-W15 current measurement
J3
SARA-R5 current measurement
J4
NORA-B1 current measurement
J6
MAX-M10 current measurement
J10
System current measurement
Table 19: Current measurement jumpers