EVK-M8BZOE User Guide
UBX-17053592 - R03
Early Production Information
Specifications
Page 8 of 33
2
Specifications
Parameter
Specification
Serial Interfaces
1 USB V2.0
1 RS232, max. baud rate 460.8 kBd
-
DB9: PC compatible
1 DDC (I
2
C compatible) max. 400 kHz
1 SPI , max. clock 1 MHz, max. data 125 kbytes/second
1 UART , max. baud rate 460.8 kBd
Dimensions
83 x 67 x 20 mm
Power Supply
5 V via micro USB connector or external powered via extra power supply pin 2 (V5_IN)
and pin 18 (GND) on digital connector
Normal Operating temperature
-20°C to +70°C
Table 2: EVK-M8BZOE specification
2.1
Safety precautions
EVK-M8BZOE must be supplied by an external limited power source in compliance with the clause 2.5 of the
standard IEC 60950-1. This power source must be a Safety Extra-Low Voltage (SELV) circuit, and only SELV circuits
are to be connected to the evaluation kit interfaces and antennas.
For more information about SELV circuits see section 2.2 in
Safety standard IEC 60950-1