C030-R412M - User Guide
UBX-19010121 - R01
Approvals
Page 23 of 27
4
Approvals
☞
For the detailed list of Radio Access Technologies and bands included in each certification
approval of the SARA-R412M modules, and for detailed instructions about how to configure the
SARA-R412M modules for certification approvals compliance perspective, see the Approvals
sections of the SARA-R4/SARA-N4 series System Integration Manual
4.1
European Conformance
The C030-R412M application board has been evaluated against the essential requirements of the
2014/53/EU Radio Equipment Directive.
In order to satisfy the essential requirements of the 2014/53/EU Radio Equipment Directive, the device
is compliant with the following standards:
Radio Frequency spectrum use (Article 3.2):
o
EN 301 511
o
EN 301 908-1
o
EN 301 908-13
o
EN 303 413
Electromagnetic Compatibility (Article 3.1b):
o
EN 301 489-1
o
EN 301 489-19
o
EN 301 489-52
Health and Safety (Article 3.1a)
o
EN 62311
o
EN 62368-1
o
EN 60950-1
The conformity assessment procedure for C030-R412M application boards, referred to in Article 17
and detailed in Annex III of Directive 2014/53/EU, has been followed.
Thus, the following marking is included in the product:
There are no restrictions for the commercialization of the C030-R412M application boards in all the
countries of the European Union.
⚠
Radiofrequency radiation exposure Information: this equipment complies with radiation exposure
limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This
equipment should be installed and operated with a minimum distance of 20 cm between the
radiator and the body of the user or nearby persons. This transmitter must not be collocated or
operating in conjunction with any other antenna or transmitter except as authorized in the
certification of the product.
⚠
The gain of the cellular system antenna(s) used for C030-R412M application boards (i.e. the
combined transmission line, connector, cable losses and radiating element gain) must not exceed
8.2 dBi in the 800 MHz band (i.e. LTE FDD-20 band), 3.21 dBi in the 900 MHz band (i.e. GSM 900 or
LTE FDD-8 band), 9.09 dBi in the 1800 MHz band (i.e. GSM 1800 or LTE FDD-3 band) for mobile and
fixed or mobile operating configurations.