ag software can be installed using the DFU bootloader or an external debugger.
Precompiled packages for each installation option are available from the u-blox C209 software
repository
Figure 9: C209 with enclosure
4.2.1
Installing tag software with the DFU bootloader using s-center
The C209 tags can be flashed over the UART using s-center
☞
Flashing requires s-center 6.1 or later.
Follow the flashing procedure outlined below when using s-center:
1.
Download and unzip the u-connectLocate software container, as described in
software with the DFU bootloader over the command line
2.
Open s-center on the correct COM port once the module is in the software download mode.
3.
Select
Software Update
.
4.
In the “Software Update” dialog, select the
app.zip
file from the software container, as shown in
. Make sure the flashing speed is set to 115200.
5.
Press
Update
.