Measurement

 

 

 

 
 

 

How to calibration? 

 

 

The way to calibration 

 

1.  Calibration:   select pixel, 100%, max resolution 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Icon 

Function 
Move 

Description 
Move or adjust the measurement tool. 

Point 

Setup > Video Overlay > Marker 

Line 

Measure length of a line. 

Vertical 

 

Rectangle 

Measure perimeter and acreage of a rectangle. 

Polygon 

Measure perimeter and acreage of a polygon. 

Circle 

 

Two Points Circle 

Measure  a  circle,  the  circle  is  determined  by  center  point 
and radius. 

Measure a circle, the circle is determined by two points. 

Three Points Circle 

Measure a circle, the circle is determined by three points. 

Arc 

Measure length of arc. 

Angle 

Measure angle. 

Calibrate 

Scale Bar 

Text 

Delete all measurement tools. 

Stitch 

Summary of Contents for HY-5099

Page 1: ...HDMIIndustrialCamera User Manual HY 5099 Industrial Camera V1 1 English Version ...

Page 2: ...ard setting of the power supply comes with the camera is 12V 1A we recommend that you use the power adapter which comes together with the camera 4 The camera should be stored under the temperature of 0 to 50 using with the humidity under 90 prevent foreign object from entering the machine do not spill liquid on the machine to prevent danger 5 Prevent knock against and violent vibration to prevent ...

Page 3: ...to blue the camera is on 3 When connecting the camera with the computer just plug the USB line is OK no need to use the power supply since USB line can power as well Language select take English as an example Press on the MENU button to enter the main menu press on the button to enter the language setting again press on the button when the English option highlight then press on the OK button to co...

Page 4: ...nter and then press on the or the button to set the image size you need Picture Scale setting Under the capture mode press on the MENU button to enter the main menu press on the button to select the Piture Scale setting and click OK button to enter and then press on the or the button to set the Piture Scale you need Mirror Contrast setting Under the capture mode press on the MENU button to enter t...

Page 5: ...harpness setting highlight then press on the OK button to enter and then press on the or the button to set what you need White balance setting Press on the MENU button to enter the main menu press on the button till white balance setting highlight then press on the OK button to enter and then press on the or the button to set Colour setting Press on the MENU button to enter the main menu press the...

Page 6: ...n to set after finishing an option press on the OK button to save and then set the other option after finishing all setting press on the MENU button to save setting and return the to main menu Frequency setting Press on the MENU button to enter the main menu press on the button till the frequency setting option highlight then press on the OK button to enter and then press on the or the button to s...

Page 7: ...ected monitor is hd monitor otherwise the resolution can not reach 1080P Second power on the microscope and connect it to the hd monitor make sure there is power on when using since there is no built in battery Third turn on the microscope put the observation on the platform and adjust the working distance to get a clear image Under the HDMI output the microscope can take picture but can not recor...

Page 8: ...ering for image previewing support for live image display of high resolution and high frame rates 3 Support dynamic image measurement function 4 The software interface is easy to operate User Interface 1 Toolbar Takepictures Recording video Browsefiles 2 Sidebar tab Switching the rightmost control panels currently provides camera control and measurement functions 3 Control panel Specific cameracon...

Page 9: ...ras preview resolution and output format Thehighest resolution is 1920x1080 Exposure and Gain If the connected camera can not support some functions such as brightness target value then the corresponding parameter can not be set up Whitebalance If the connected camera can not support some functions such as brightness target value then the corresponding parameter can not be set up Red Green and Blu...

Page 10: ... Rectangle Measure perimeter and acreage of a rectangle Polygon Measure perimeter and acreage of a polygon Circle Two Points Circle Measure a circle the circle is determined by center point and radius Measure a circle the circle is determined by two points Three Points Circle Measure a circle the circle is determined by three points Arc Measure length of arc Angle Measureangle Calibrate Scale Bar ...

Page 11: ...icatior Actual Length Meter 4 After select calibration choose the unit and multiplying power you need then you can calibrate How to set cross hair on measure software 1 First step select setup 2 Second step select video overlay 3 Third step select the Cross in Type ...

Page 12: ...ystems Windows 7 Windows8 Windows10 Linux Theoperating environment Microsoft Net Framework 4 0 Microsoft Visual C 2010 If there is no the two complete runtime library there will be an error when installing the software If you are unable to enter the link or download the files please contact with the customer service After downloading successfully open the zipped files and install the software ...

Reviews: