TZS First AUSTRIA FA-2461-2-WI Instruction Manual Download Page 2

2

3

ENGLISH

FEATURES:

•  Time in optional 12/24 hour format.

•  Date and weekday display

•  Continuous calendar up to 2099

•  Two daily alarms

•  Automatic snooze function

•  Barometer: Graphic display to show the air 

pressure, display either in mb/hPa or inHg, air 

pressure trend display

•  Weather forecast using five icons: sunny, light 

cloud cover, cloudy, rain and stormy

•  Temperature alternatively in°C or°F

•  Temperature cozy icon display.

• Thermometer: 

  Indoor measurement ranges: 0°C (32°F) ~ 

50°C (122°F) (calibration time: 30 seconds),

  outdoor measurement ranges: -22°C (-3.8°F) 

~ 50°C (122°F) (calibration time: 30 seconds),

•  Hygrometer: Measurement range: 20%-95% .

•  Minimum/maximum display for air humidity 

and temperature

•  Temperature alert 

•  Moon phase display.

•  LED back light display (auto off after 8 

seconds in battery powered, DC power 

supply has always been).

•  Power Supply: 

  Weather Station:

  Battery: 2 x LR6 AA

  DC-POWER: DC 4.5V 200mA

  Wireless Outdoor Sensor: 

  Battery: 2 x LR6 AA

LCD SCREEN AND SETTINGS:

(Fig A)

1.  Air pressure icon

2.  Weather forecast

3.  Air pressure time history

4.  Histogram shows the trend of 12 hours of 

atmospheric pressure

5. 

Air pressure values

6.  Time

7.  SNOOZE icon

8. 

Temperature alert

9.  Cozy icon

10. 

RF icon

11. Channel cycle

12. 

Indoor temperature values

13. Indoor temperature trend

14. Main unit low battery icon

15. Indoor humidity trend

16. 

Indoor humidity values

17. Outdoor temperature trend

18. 

Outdoor sensor low battery icon

19. Outdoor humidity trend

20. 

Outdoor humidity values

21. 

Outdoor temperature values

22. Moon phase icon

23. Week

24. Date

25. Alarm icon

26. Channel selection

Main Unit Structure function description

(Fig B)

a)  SNOOZE/LIGHT functional touch area

b)  Button operation panel

c)  Insertion position of power supply

d)  Battery mount position

WIRELESS OUTDOOR SENSOR 

(Fig C)

C1: LCD display – Temperature

C2: LCD display – Humidity

C3: LCD display – RF icon

C4: LED icon by RF

C5: “C°/F°” button

C6: “TX” button

C7: Battery compartment

Wireless remote sensor (transmitter) 

•  Transmitter frequency: 433.92 MHz.

•  Range of transmission is up to 60m 

(200 feet).

•  Insert the 2 batteries in to the transmitter. Pay 

attention to observe the correct polarity.

INITIAL OPERATION:

•  Open Weather Station battery compartment 

cover 

•  Insert 2 x AA batteries observing polarity [ “+” 

and “ –“ marks] 

•  When you insert the batteries, all the icon 

on the LCD display will briefly light up for 3 

seconds, and you will hear a beep tone, and 

detect indoor temperature & humidity.

•  The Weather Station will now start to make 

a connection to the outdoor remote sensor. 

This operation takes about 3 minutes and is 

displayed by a flashing reception RF antenna 

symbol in the “OUT” display area on the 

receiver.

•  This now, replace Wireless Outdoor Sensor 

battery compartment cover. Open Weather 

Station battery compartment cover. Insert 2 

x AA batteries observing polarity [ “+” and “–“ 

marks] 

•  After receiver has created a connection to the 

outdoor remote sensor, it will then b enters 

the clock mode.

MANUAL TIME SETTING:

•  Press and hold down the “SET/HISTORY” 

button for two seconds.

•  The year display “2012” starts to flash. Now 

use “UP” and “DOWN/

” to set the correct 

year.

•  Press “SET/HISTORY” to confirm your 

setting.

•  The month display starts to flash. Now use 

“UP” and “DOWN/

” to set the correct month

ENGLISH

•  Press “SET/HISTORY” to confirm your 

setting.

•  The date display starts to flash. Now use 

“UP” and “DOWN/

” to set the correct date.

•  Press “SET/HISTORY” to confirm your 

setting. 

•  There are 7 languages of Weekday: German, 

English, Italian, French, Dutch, Spanish, and 

Danish, press “UP” and “DOWN/

” to select.

•  Press “SET/HISTORY” to confirm your 

setting.

•  The time is displayed either in 12 or 24 

hour format. Briefly pressing the “UP” and 

“DOWN/

” button allows you to switch 

between the individual modes. The symbol 

AM (before midday) or PM (after midday) 

appears after the time.

•  Press “SET/HISTORY” to confirm your 

setting.

•  The hour display starts to flash. Now use 

“UP” and “DOWN/

” to set the correct hour.

•  Press “SET/HISTORY” to confirm your 

setting.

•  The minute display starts to flash. Now 

use “UP” and “DOWN/

” to set the correct 

minute.

•  Press “SET/HISTORY” to confirm your 

setting.

•  The Time zones start to flash, Now use “UP” 

and “DOWN/

” buttons to set a correct time 

zone (-12 to +12).

•  Press “SET/HISTORY” to confirm your 

setting.

•  The weather icon display starts to flash. Now 

use “UP” and “DOWN/

” to set the weather 

of the day

•  Press “SET/HISTORY” to confirm your 

setting.

•  The air pressure unit display starts to flash. 

Now use “UP” and “DOWN/

” to calibrate 

current air pressure deviation

•  Press “SET/HISTORY” to confirm your 

setting.

•  The air pressure unit display starts to flash. 

Now use “UP” and “DOWN/

” to set the mb/

hPa or in Hg

SETTING THE DAILY ALARMS:

The weather station possesses has two daily 

alarms. To view the set alarm times, press 

the “ALARM/SET” button briefly. The display 

switches from the clock to Alarm 1 and, if you 

press the button again, to Alarm 2. (In eight 

seconds, the weather stations automatically 

return to the normal time display.)

Proceed as follows to set the daily alarm:

•  Press and hold down the “ALARM/SET” 

button for two seconds until alarm time 1 and 

the flashing icon are displayed.

•  Now use the “UP” and “DOWN/

” buttons 

to select the alarm time you require and then 

briefly press the “ALARM/SET” button to set 

this time.

•  The hour display of the alarm time starts 

to flash. Use the arrow keys “UP” and 

“DOWN/

” buttons to set the required hour.

•  Press “ALARM/SET” to confirm your setting

•  The minute display of the alarm time starts 

to flash. Use the arrow keys “UP” and 

“DOWN/

” to set the required minute.

•  Press “ALARM/SET” to confirm your setting 

and to end the setting procedure.

Activation and deactivating the daily alarms:

•  To activate or deactivate the daily alarms, 

briefly press the “DOWN/

” button:

  Press 1x: Alarm 1 activated

  Press 2x: Alarm 2 activated

  Press 3x: Both alarms are activated

  Press 4x: Both alarms deactivated

Information:

•  After eight seconds without a button being 

pressed, the clock switches automatically 

from setting mode to Normal clock mode.

•  The alarm will sound for two minutes if you 

do not deactivate it by pressing any button. 

In this case, the alarm will be repeated 

automatically after 24 hours.

•  Rising alarm (length: 2 minutes) changes the 

volume four times whilst the alarm signal is 

heard.

•  Press “SET/HISTORY” or “ALARM/SET” 

button to deactivate the alarm.

Automatic snooze function

•  Proceed as follows to activate the automatic 

snooze function:

  While the alarm is sounding, press touch the 

“LIGHT/SNZ” to activate the snooze function. 

When the snooze function is active, the “Zz” 

symbol appears in the display.

•  This operation moves the alarm back by five 

minutes and the alarm will restart at this time

•  The snooze function can be interrupted by 

pressing any button or repeated up to seven 

times

•  Press “SET/HISTORY” or ”ALARM” button to 

deactivate the snooze function.

°C/°F temperature display

•  The temperature is displayed either in °C/°F. 

Briefly pressing the °C/°F button allows you to 

switch between the individual modes.

Temperature trend display

After you insert the batteries, the weather station 

measures the current temperature. The trend  

 

Reviews: